background image

Doc: 

101547

-GB-2140

25

 

Bergvägen 7 | SE-341 32 Ljungby | Sweden • Tel +46 (0)372-156 00 | www.swepac.com

F82B
F92B

CONSUMER INFORMATION

HONDA DC power unit GXE2.0H

Warranty and Distributor/Dealer Locator Information

United States, Puerto Rico, and U.S. Virgin Islands:

Visit our website: www.engines.honda.com

Canada:

Call (888) 9HONDA9

or visit our website: www.honda.ca

For European Area:

Visit our website: http://www.honda-engines-eu.com

Customer Service Information

Servicing dealership personnel are trained professionals.

They should be able to answer any question you may 

have.

If you encounter a problem that your dealer does not 

solve

to your satisfaction, please discuss it with the dealership’s

management. The Service Manager, General Manager, or

Owner can help.

Almost all problems are solved in this way.

United States, Puerto Rico, and U.S. Virgin Islands:

If you are dissatisfied with the decision made by the

dealership’s management, contact the Honda Regional 

Engine Distributor for your area. You can find their name, 

address, and phone number using the distributor/dealer 

locator on our website at www.engines.honda.com

If you are still dissatisfied after speaking with the Regional 

Engine Distributor, you may contact the Honda Office.

American Honda Motor Co., Inc.

Power Equipment Division

Customer Relations Dept.

4900 Marconi Drive

Alpharetta, GA 30005-8847

Or telephone: (770) 497-6400, M-F 9:00 am - 7:30 pm ET

All Other Areas:

If you are dissatisfied with the decision made by the 

dealership’s management, contact the Honda Office.

Honda DC Power Unit International Warranty

The Honda DC Power Unit (including Battery Pack and Battery Charger) installed on 

this brand product is covered by a Honda DC Power Unit Warranty, on the following 

assumptions.

- The warranty conditions conform to those for the DC Power Unit established by Honda for 

each country.

- The warranty conditions apply to DC Power Unit failures caused by any manufacturing or 

specification problem.

- The warranty does not apply to countries where there is no Honda distributor who deals DC 

Power Unit.

To obtain warranty service:

You must take your Honda DC Power Unit, or the equipment in which it is installed, together 

with proof of original retail purchase date to the dealer who you purchased your product 

from or a Honda dealer authorized to sell that product in your country. To locate a Honda 

distributor/dealer near you or check warranty condition in your country, visit our global 

service information website

https://www.hondappsv.com/ENG/ or contact distributor in your country.

Scan

Exclusions:

This DC Power Unit warranty does not include the following:

1. Any damage or deterioration resulting from the following:

- Neglect of the periodic maintenance as specified in the DC Power Unit owner’s manual

- Improper repair or maintenance

- Operating methods other than those indicated in the DC Power Unit owner’s manual

- Damage caused by the product on which the DC Power Unit is installed

- The use of non-genuine Honda parts and accessories, other than those approved by Honda

- Exposure of the product to soot and smoke, chemical agents, bird droppings, sea water, sea 

breeze, salt or other environmental phenomena

- Collision, neglect, unauthorized alteration, or misuse

- Natural wear and tear (natural fading of painted or plated surfaces, sheet peeling and other 

natural deterioration)

2. Consumable parts: Honda does not warrant normal decrease of battery full-charge 

capacity due to usage and storage, and parts deterioration due to normal wear and tear.

3. Cleaning, adjustment, and normal periodic maintenance work.

4. Use of the Honda DC Power Unit for racing or competition.

5. Any DC Power Unit that is part of a product that has ever been declared a total loss or sold 

for salvage by a financial institution or insurer.

Содержание F 82B

Страница 1: ...F 82B F92B FOR A SOLID GROUND USER MANUAL IN ORIGINAL Doc 101547 GB 2140...

Страница 2: ...wer unit installed in the machine Do not use a non genuine battery pack Using a non genuine battery pack could damage itself and the DC power unit because of poor protection functions etc INTRODUCTION...

Страница 3: ...GNS 6 SAFETY INSTRUCTIONS 7 MACHINE SIGNS AND IDENTIFICATION 9 COMPONENT CONTROL LOCATIONS 10 MAINTENANCE 13 PRE OPERATION 14 FUNCTION OVERVIEW 15 OPERATION 15 CHARGING PROCEDURE 15 OPTIONS 17 TRANSPO...

Страница 4: ...OUR INFORMATION ON DC POWER UNIT ATTACHMENT DC power unit safety functions include a function 1 to safely turn off torque to the motor when a stop signal is sent from the START STOP switch and a funct...

Страница 5: ...its for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipme...

Страница 6: ...he belt drive when the machine is on to avoid injury and damage See the safety instructions in the manual As the sound pressure level at the operator s ears exceeds 80 dB A ear protectors must be used...

Страница 7: ...er property or the environment Battery pack safety Failure to follow the instructions below may result in excessive heat fire and or bursting explosion etc Do not heat or place into fire Do not use ch...

Страница 8: ...safety 1 Before using the battery charger read all instructions and cautionary markings on battery charger battery pack and product using battery pack 2 CAUTION To reduce risk of injury charge only D...

Страница 9: ...the battery charger to excessive physical shock such as by dropping or hitting it Do not use the battery charger to charge anything except Honda battery packs Use only authentic battery packs Chargin...

Страница 10: ...com F82B F92B COMPONENT CONTROL LOCATIONS 1 B00022 5 2 3 4 1 8 7 6 9 12 11 13 10 14 Handle 2 DC power unit 3 V belt wheel 4 Motor plate 5 Protective cover 6 V belt 7 Rubber damper 8 Base plate 9 Vibra...

Страница 11: ...2 3 4 5 1 POWER button 2 START STOP switch 3 POWER indicator green light 4 ALERT indicator yellow light 5 ERROR indicator red light Battery ALERT ERROR B00041 8 7 6 5 3 4 2 1 1 Grip 2 Intake port bot...

Страница 12: ...k 2 Battery tray 3 Battery connector cap 4 Power cable 5 Battery fastener 6 Battery fastener lever 7 Rubber support Battery charger B00043 4 5 6 9 8 1 2 7 7 7 3 1 Charging cable 2 Charging connector 3...

Страница 13: ...Power cables Check o Wires harness Check o 2 4 Battery fastener Check o Replace o o 2 Rubber support power unit Check o Replace o 2 Battery hook Check o Replace o 2 Rubber mount power unit Replace o...

Страница 14: ...is stable Dry and well ventilated location Optimal charging at room temperature Battery packs shall be charged at temperatures between 5 C 41 F and 30 C 86 F Pre operation checks for DC power unit Che...

Страница 15: ...e POWER indicator turns off Press the POWER button again to start the machine Checking the charge level of the battery pack While the machine is operating the charge level indicator lights or flashes...

Страница 16: ...he charging connector 4 to the battery connector 5 All the indicators on the battery charger and the battery pack light for about one second After that just the battery charger s POWER indicator light...

Страница 17: ...when working on asphalt Stop the water supply by turning the water tap clockwise B00044 2 6 5 1 3 4 Disassemble the water tank doing as follow Push the locking ring on the coupling 1 towards the water...

Страница 18: ...1 by pulling the motor 2 towards the operator side Tighten the four screws Reassembly the cover in the reverse order Check the condition of the four rubber dampers 3 regularly Replace damaged dampers...

Страница 19: ...on packaging and labelling must be observed For preparation of the item being shipped consulting an expert for hazardous material is required Ship battery packs only when undamaged Observe the possibi...

Страница 20: ...become unusable Charge the battery pack until from 1 to 3 charging level indicators are lit On Flashing Off Battery charger Before storing the battery charger remove the battery pack from the battery...

Страница 21: ...utton DC power unit becomes hot POWER indicator lights Stop using the machine and wait for the DC power unit to cool down ERROR indicator is lit Possible cause Solution Protection function is engaged...

Страница 22: ...for the battery pack problem connect the specified device and check if it works properly When the device works the battery pack can be used normally 1 indicator flashes Problem was detected Low voltag...

Страница 23: ...H H H B00030 F82B F92B Metric Imperial H 620 mm 24 8 in H1 990 mm 38 9 in H2 980 mm 38 5 in L 1070 mm 42 1 in L1 610 mm 24 in W 430 mm 500 mm 16 9 in 19 7 in Machine with standard handle L L W H H H B...

Страница 24: ...1 rpm Current 27 A Voltage 72 V Net power 1 8 kW 2 4 HP 2 4 PS 3 600 min 1 rpm Torque 5 6 N m 0 57 kgf m 3 600 min 1 rpm Voltage 72 V Set speed Rated speed 3 600 min 1 rpm Battery pack operating tempe...

Страница 25: ...for the DC Power Unit established by Honda for each country The warranty conditions apply to DC Power Unit failures caused by any manufacturing or specification problem The warranty does not apply to...

Страница 26: ...Doc 101547 GB 2140 26 Bergv gen 7 SE 341 32 Ljungby Sweden Tel 46 0 372 156 00 www swepac com F82B F92B NOTES...

Страница 27: ...rmity Manufacturer Swepac AB Bergv gen 7 34132 Ljungby 1 Category Vibratory plate 2 Type F82B F92B 3 Engine power 1 6 kW The product complies with the following directives 2006 42 EG 2000 14 EG 2004 1...

Страница 28: ...Bergv gen 7 SE 341 32 Ljungby Sweden Tel 46 0 372 156 00 www swepac com FOR A SOLID GROUND...

Отзывы: