Users Manual Area Scan Cameras SVSGigE
Page 10
Users Manual –svs11002 and svs16000
© SVS-VISTEK GmbH
The camera puts out data automaticly. The framerate can be adjusted.
Triggered, external exposure control
If you want to trigger the camera and determine the exposure time by the pulse
width of Exsync, choose this mode. Then apply a TRIGGER signal at the
appropriate pins e.g. on pins of Hirose connector (see Layout for Connector.
With the starting edge of the pulse the camera will start exposure time. The
exposure time ends with next upcoming edge of Exsync. Please check the
timing diagram in the appendix of this manual.
External triggered, internal camera exposure control
If you want to trigger the camera and use the convenient exposure time control
of the micro controller then use this mode. You still can use the SVCapture GUI
for setting exposure time (see “Exposure time”-field below). However you need
to use the Exsync signal in order to trigger the camera (see “Trigger”-buttons
below).
External triggered via Software trigger with internal exposure control
If you want to trigger the camera with a software trigger and use the
SVCapture exposure time control of camera logic then use this mode.