28/30
ALFA IN a.s ©
www.alfain.eu
17. ERROR MESSAGES
Error messages appear on the machine display. At the same time, a QR code is
displayed, which allows you to open the legend of error messages on mobile
phones.
Error code
Symbol Fault / Solution procedure
E01
QR code
Power module overload. Call service
+420 563 034 626.
E02
Overheating. Stop cutting and allow the
machine to cool down.
E03
Defective MUR diode module; bad IGBT
block; faulty driver or cabling. Call
s420 563 034 626.
E04
There was no pilot arc ignition. Check
the supplies.
E05
Consumables in the burner did not
separate during ignition, probably due to
a jam. Check the supplies.
E06
QR code
PFC is not connected. Call service
+420 563 034 626
E07
QR code
The mains voltage is over 460 V AC.
Check power supply.
E08
QR code
The mains voltage is below 340 V AC.
Check power supply.
E09
QR code Phase failure. Check power supply.
E11
Incorrectly assembled burner
consumables. Fix it.
E13
Low output pressure (below 2,7 bar) or
no input pressure. Check the air supply.
E14
QR code
The torch button was pressed during
start-up. It is necessary to restart the
machine.