7.
The minimal size of an air tank is 100 l.
8.
No additional oiling if the pressure air is permitted. That could damage the
plasma machine and the cutting torch.
Note
Some compressors have a built-in compressed air lubricator
at the outlet. The plasma cutter must never be connected to this output!
This would contaminate the entire pneumatic system and damage the
burner.
CONNECTION TO CENTRAL DISTRIBUTION
1. Before connecting, determine the working pressure in the system and the
extent of its fluctuations
2. When cutting, the working pressure must be in the range of 5.0 - 6.0 bar.
To achieve maximum cutting power, we recommend that the pressure
does not fall below 5.5 bar.
3. Check the performance and technical condition of the central compressor
(s). The same requirements as above apply here.
4. Check the design and condition of the compressed air filtration and
condensate trap.
5. Make sure the system is not centrally lubricated.
6. Insert an additional filter and separator at the connection point as close as
possible to the cutter. This is especially important for older distribution
systems made of conventional steel pipes, where the inner walls can be
considerably corroded. It is necessary to use a filter with a sludge trap in
systems with long distributions that pass through a cold environment,
where compressed air can cool to the dew point and thus condense water
droplets.
BALANCE AIR FILTER FOR SVAROG 105 PLASMA
In order to achieve high cutting quality and to avoid serious faults on the torch,
it is strongly recommended that a filter be always included in the inlet - Fig. 4.
Pos.
Code
Description
25
5304
Filter - set AT 1000 k SVAROG PLASMA
24
5302
Air filter AT 1000
Note
Max. operating pressure of the AT 1000 filter is 8.5 bar.