ELECTRICAL SYSTEM 6-17
Measure the relay coil resistance between the terminals with the
multi-circuit tester. If the resistance is not within the standard
range, replace the starter relay with a new one.
\
09900-25008: Multi-circuit tester set
V
Tester knob indication: Resistance (
W
)
Starter relay resistance: 3 – 6
W
• Tighten the starter relay lead wire mounting bolt to the speci-
fied torque.
"
Starter relay lead wire mounting bolts:
4.5 N·m (0.45 kgf-m, 3.0 lb-ft)