Rev. 2.4
- 54 -
© 2014 Suzo-Happ Group
Bill-to-
Bill™ 300XE
The spring arm (
8601001)
can also be replaced at this point to ensure a smooth and safe opening and
closing of the cassis and to avoid damage to the connectors between the two halves of the chassis.
When reinstalling the gas piston, the orientation of the spring is essential and the rod side must be
installed downwards away from the switch as seen in the image above.
Before completing the level 3 maintenance, ensure none of the connectors for the dispenser and
recycling cassettes are loose or damaged due to misuse and repetitive insertion cycles.
Finally, for the rest of the components perform the same maintenance steps as in Level 2
maintenance.
After all steps have been performed and the chassis has been put together, place the
chassis on the P2258 fixture in order to verify all other components are working properly. If
any issues are detected, change parts and required.
6.3.
Path Switch (BBS-0110)
Due to the high traffic of bills the switch has undergone at this point, it must be replaced by a new unit
at this point.
For steps on how to properly replace the path switch module please go to section 4.4.