![Suzohapp Bill to Bill 300XE Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/suzohapp/bill-to-bill-300xe/bill-to-bill-300xe_serviceability-manual_1408250047.webp)
Rev. 2.4
- 47 -
© 2014 Suzo-Happ Group
Bill-to-
Bill™ 300XE
6.
Level 3 maintenance
This level of preventative maintenance restores the Bill-to-Bill
™ 300XE unit from the effects of
temperature cycling through the day and thought out the year as well as from extensive wear due to
normal operating mode. In this level it is recommended to replace the transport belts, o-rings and
rollers within the unit as well as several sensors, security features and motors. For recommended
period of service please refer to the Maintenance Chart in section 7. Additionally, this level is
performed in parallel with the steps in level 1 and level 2 maintenances for that maintenance period.
It is essential to perform all steps in this level in a sterile and anti-static environment as outlined in the
Suzo-Happ Group
Maintenance Guidelines
document. Additionally, all torque values applied when
re-assembling the modules must also be applied with accordance to the Suzo-Happ Group
Bill-to-Bill
™ Assembly Guidelines
document.
Level
Location
Responsibility
Service time (per unit)
3
Workshop
Service Center Technician
2-3h
The tools required for this level are:
1) Can of compressed air
2) Alcohol-free LCD cleaner
3) Anti-static microfiber cloth
4) A set of cotton swabs
5) Dummy card
6) Tweezers
7) Philips screwdriver (PH1 x 60)
8) Flathead screwdriver (3,0 x 60)
9) Cleaning card for
bank note acceptor
10) A pair of gloves
- Sense-A-
Click™ Extractor
(purchased separately)
Ensure the recycling cassette has been properly and safely unloaded before performing
the following maintenance steps
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)