NICE3000
new
User Manual System Commissioning and Application Example
- 83 -
Table 5-2 Output state of the running and brake contactors
Control mode
Output State
No-load Auto-
tuning
(F1-11 = 2)
With-load Auto-tuning
(F1-11 = 1)
Operation
Panel
Control
(F0-01 = 0)
Distance
Control
(F0-01 = 1)
Synchronous
motor
Asynchronous
Motor
RUN contactor
Output
Output
Output
Not output
Output
Brake contactor
Not output
Output
Not output
Not output
Output
5.1.3 Trial Running at Normal Speed
After ensuring that running at inspection speed is normal, perform shaft auto-tuning, and
then you can perform trial running at normal speed (the elevator satisfies the safety running
requirements).
To perform shaft auto-tuning, the following conditions must be satisfied:
1. The signals of the encoder and leveling sensors (NC, NO) are correct and the slow-
down switches are installed properly and act correctly.
2.
When the elevator is at the bottom floor, the down slow-down 1 switch acts.
3. The elevator is in the inspection state. The control mode is distance control and CLVC
(F0-00 = 1, F0-01 = 1).
4.
The top floor number (F6-00) and bottom floor number (F6-01) are set correctly.
5. The system is not in the fault alarm state. If there is a fault at the moment, press
STOP
RES
to reset the fault.
Then set F1-11 to 3 on the operation panel or set F7 to 1 on the keypad of the MCB, and
start shaft auto-tuning.
Note
For shaft auto-tuning when there are only two floors, the elevator needs to run to below the bottom
leveling position, that is, the leveling sensor is disconnected from the leveling plate. There is no
such requirement when there are multiple floors.
5.1.4 Door Machine Commissioning
Correlation of the door machine controller and the elevator controller is that the CTB outputs
door open/close command and the door machine controller feeds back the door open/close
limit signal.
After commissioning and installation of the door machine are complete, check whether the
wiring is correct and whether the door open/close limit signals are consistent with the default
setting. To perform the door machine commissioning, do as follows:
1. In the terminal control mode of the door machine controller, manually short the door
open relay output terminal BM/B1 and the door close relay output terminal BM/B2 on
the CTB, and observe whether the door machine can open and close correspondingly.
Содержание NICE3000 New
Страница 1: ......
Страница 13: ......
Страница 14: ...1 Safety Information and Precautions ...
Страница 21: ...Safety Information and Precautions NICE3000new User Manual 20 ...
Страница 22: ...2 Product Information ...
Страница 33: ...Product Information NICE3000new User Manual 32 ...
Страница 34: ...3 Mechanical and Electrical Installation ...
Страница 67: ...4 Use of the NICE3000new ...
Страница 79: ...5 System Commissioning and Application Example ...
Страница 105: ...6 Function Code Table ...
Страница 136: ...Function Code Table NICE3000new User Manual 134 ...
Страница 137: ...7 Description of Function Codes ...
Страница 205: ...8 EMC ...
Страница 214: ...EMC NICE3000new User Manual 212 ...
Страница 215: ...9 Troubleshooting ...
Страница 230: ......
Страница 233: ......