Description of Function Codes NICE3000
new
User Manual
- 156 -
Figure 7-5 Example of LED display indicating the communication state
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F5-33
Terminal program control
0–65535
0
-
★
It is used to set the elevator functions. Whether a function is enabled is indicated by a binary
bit: "1" indicates that the function is enabled, and "0" indicates that the function is disabled.
The functions defined by the binary bits are described in the following table.
Table 7-3 Functions indicated by bits of F5-33
Bit
Function
Description
Default
Bit3
Elevator fire emergency
requirement for Hong
Kong
If it is enabled, the fire emergency functions in
F6-44 applied to Hong Kong become enabled
automatically.
0
Bit4 Arrival gong disabled at
night
The arrival gong is disabled from 22:00 p.m. to
7:00 a.m.
0
Bit6
Door lock disconnected at
inspection switched over
to normal running
The door lock is additionally disconnected once
when the inspection state is switched over to the
normal running state.
0
Bit7 Fault code not displayed
on the keypad
The keypad does not blink to display the fault code.
0
Bit8
Door open command
cancelled immediately at
door open limit
The system immediately cancels the door open
command after receiving the door open limit.
0
Bit9
Car stop and zero-speed
torque holding at abnormal
brake feedback
When the brake feedback is abnormal, the elevator
arrives at the door-zone position and stops. The
door keeps closed, and the system holds torque
output as long as possible. After the system is
over-loaded, there is no torque output, and the
elevator may fall in this case. Be cautious of using
this function.
0
Function Code
Parameter Name
Setting Range
Default Unit Property
F5-34
Terminal state display Monitoring of I/O terminals
on MCB
-
-
●
F5-35
Terminal state display Monitoring of I/O terminals
on CTB, CCB and HOP
-
-
●
Содержание NICE3000 New
Страница 1: ......
Страница 13: ......
Страница 14: ...1 Safety Information and Precautions ...
Страница 21: ...Safety Information and Precautions NICE3000new User Manual 20 ...
Страница 22: ...2 Product Information ...
Страница 33: ...Product Information NICE3000new User Manual 32 ...
Страница 34: ...3 Mechanical and Electrical Installation ...
Страница 67: ...4 Use of the NICE3000new ...
Страница 79: ...5 System Commissioning and Application Example ...
Страница 105: ...6 Function Code Table ...
Страница 136: ...Function Code Table NICE3000new User Manual 134 ...
Страница 137: ...7 Description of Function Codes ...
Страница 205: ...8 EMC ...
Страница 214: ...EMC NICE3000new User Manual 212 ...
Страница 215: ...9 Troubleshooting ...
Страница 230: ......
Страница 233: ......