System Commissioning and Application Example NICE3000
new
User Manual
- 102 -
When there is a hall call at the VIP floor, the system automatically enters the VIP state. After
the VIP input terminal is ON, the elevator returns to the VIP floor to provide the VIP service.
The VIP running times is limited by bit8 of F6-46. If bit8 is set to 1, the elevator responds to
only one car call (the last one); after arriving at the floor required by the car call, the elevator
automatically exits the VIP state. If bit8 is set to 0, the number of car calls is not limited.
The elevator automatically exits the VIP state if it does not enter the car call running within
30s after each time stop or after it executes all car calls. If there is no car call 30s after the
elevator enters the VIP state, the elevator automatically exits the VIP state.