Group F9: Time Parameters
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F9-00
Idle time before
returning to base floor
0–240
10
min
☆
It is used to set the idle time of the elevator before returning to the base floor.
When the idle time of the elevator exceeds the setting of this parameter, the elevator returns
to the base floor.
If this parameter is set to 0, it becomes invalid.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F9-01
Time for fan and lamp
to be turned off
0–240
2
min
☆
It is used to set the time that fan and lamp stays ON before being turned off automatically.
If there is no running command in the automatic running state, the system turns off the fan
and lamp automatically after the time set in this parameter.
If this parameter is set to 0, it becomes invalid.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F9-02
Motor running time limit
0–45
45
s
★
It is used to set the running time limit of the motor.
In normal running state, if the continuous motor running time in the same direction between
two adjacent floors exceeds the setting of this parameter but no leveling signal is received,
the system will perform protection.
This parameter is mainly used for over-time protection in the case of steel rope slipping on
the traction sheave.
If this parameter is set to a value smaller than 3s, it becomes invalid.
Function Code
Parameter Name
Setting Range
Default
Unit
Property
F9-03
Clock: year
2000–2100
Current year
YYYY
☆
F9-04
Clock: month
1–12
Current month
MM
☆
F9-05
Clock: day
1–31
Current day
DD
☆
F9-06
Clock: hour
0–23
Current hour
HH
☆
F9-07
Clock: minute
0–59
Current minute
MM
☆
These parameters are used to set the current date and time of the system.
Timekeeping is supported at power failure. You need to set the current system time correctly
so that functions related to the time can be implemented.
Содержание NICE3000 New
Страница 1: ......
Страница 13: ......
Страница 14: ...1 Safety Information and Precautions ...
Страница 21: ...Safety Information and Precautions NICE3000new User Manual 20 ...
Страница 22: ...2 Product Information ...
Страница 33: ...Product Information NICE3000new User Manual 32 ...
Страница 34: ...3 Mechanical and Electrical Installation ...
Страница 67: ...4 Use of the NICE3000new ...
Страница 79: ...5 System Commissioning and Application Example ...
Страница 105: ...6 Function Code Table ...
Страница 136: ...Function Code Table NICE3000new User Manual 134 ...
Страница 137: ...7 Description of Function Codes ...
Страница 205: ...8 EMC ...
Страница 214: ...EMC NICE3000new User Manual 212 ...
Страница 215: ...9 Troubleshooting ...
Страница 230: ......
Страница 233: ......