Mechanical and Electrical Installation NICE3000
new
User Manual
- 64 -
Table 3-17 Slow-down distances based on different rated elevator speeds
Rated Elevator Speed
V ≤ 1.5 m/s
1.5 m/s < V ≤ 2.4 m/s
2.4 m/s < V ≤ 3.7 m/s
Distance of slow-down 1
1.3 m to H/2
1.3 m
1.3 m
Distance of slow-down 2
-
3.2 m
3.2 m
Distance of slow-down 3
-
-
8.0 m
Note
• "H" in the table indicates the landing height. The slow-down 1 will reset the terminal floor
display, and the slow-down 1 switch needs to be installed within H/2.
•
The slow-down distances above are calculated on the basis of the default values (special
deceleration rate 0.9 m/s
2
, and acceleration rate and deceleration rate 0.6 m/s
2
).
•
Increasing the acceleration rate and deceleration rate or reducing the special deceleration rate
may bring safety hazard. If any change is need, re-calculate the slow-down distance by using
the above formula.
3.8.3 Installation of Limit Switches
The up limit switch and down limit switch is to protect the elevator from over travel top/
bottom terminal when the elevator does not stop at the leveling position of the terminal floor.
•
The up limit switch needs to be installed 30−50 mm away from the top leveling position.
The limit switch acts when the car continues to run upward 30−50 mm from the top
leveling position.
•
The down limit switch needs to be installed 30−50 mm away from the bottom leveling
position. The limit switch acts when the car continues to run downward 30−50 mm from
the bottom leveling position.
3.8.4 Installation of Final Limit Switches
The final limit switch is to protect the elevator from over travel top/bottom terminal when the
elevator does not stop completely upon passing the up/down limit switch.
•
The up final limit switch is mounted above the up limit switch. It is usually 150 mm away
from the top leveling position.
•
The down final limit switch is mounted below the down limit switch. It is usually 150 mm
away from the bottom leveling position.
Содержание NICE3000 New
Страница 1: ......
Страница 13: ......
Страница 14: ...1 Safety Information and Precautions ...
Страница 21: ...Safety Information and Precautions NICE3000new User Manual 20 ...
Страница 22: ...2 Product Information ...
Страница 33: ...Product Information NICE3000new User Manual 32 ...
Страница 34: ...3 Mechanical and Electrical Installation ...
Страница 67: ...4 Use of the NICE3000new ...
Страница 79: ...5 System Commissioning and Application Example ...
Страница 105: ...6 Function Code Table ...
Страница 136: ...Function Code Table NICE3000new User Manual 134 ...
Страница 137: ...7 Description of Function Codes ...
Страница 205: ...8 EMC ...
Страница 214: ...EMC NICE3000new User Manual 212 ...
Страница 215: ...9 Troubleshooting ...
Страница 230: ......
Страница 233: ......