16
Figure 10 - Removing Thermostat Sensing Bulb
Retaining
Clamp
Thermostat
Sensing Bulb
Capillary
Adhesive-
Backed
Mounting
Clip
Figure
11
-
Locating
Thermostat Sensing Bulb on
Masonry Fireplace
Thermostat
Sensing
Bulb
Adhesive-
Backed
Mounting
Clip
Thermostat
Sensing
Bulb
Figure 12 - Locating Thermostat
Sensing Bulb on Factory-built
Metal Fireplace
Adhesive-
backed
Mounting
Clip
Glass Doors
Thermostat
Sensing
Bulb
Figure 13
-
Installing
Thermostat Sensing Bulb
behind Glass Doors
Capillary
Thermostat
Sensing Bulb
Do Not
Crimp
Capillary
Adhesive-
backed
Mounting
Clip
Figure 14
- Positioning the
Thermostat Sensing Bulb in
the Vertical Position with the
Capillary at the Bottom
OPTIONAL POSITIONING OF
THERMOSTAT SENSING BULB
Check pilot
flame
pattern
and
burner
flame
patterns
of-
ten.
INSPECTING BURNERS
PILOT FLAME PATTERN
Figure
15
shows
a
correct
pilot
flame
pattern.
Figure
16
shows
an
incorrect
pilot
flame
pattern.
The
incorrect
pilot
flame
is
not
touching
the
flame
sensor.
This
will
cause
the
flame
sensor
to
cool.
When
the
flame
sensor
cools,
the
heater will shut down.
If pilot flame pattern is incorrect, as shown in Figure 16:
• turn heater o
ff
( See
To Turn Off Gas
To Appliance,
page 15).
•
see
Cleaning and Maintenance,
page 17.
Note: The correct pilot
flame
on natural gas units will
have a slight curve, but
flame
should be blue and have no
yellow or orange color.
Figure 15 - Correct Pilot Flame Pattern
Figure 16 - Incorrect Pilot Flame Pattern
Thermocouple
Pilot Burner
Pilot Burner
Thermocouple
Содержание RIVERSIDE OVT22LP