background image

3

1. This appliance is only for use with the type of gas

indicated on the rating plate. This appliance is not

convertible for use with other gases. 

2. Do not place propane/LP supply tank(s) inside any

structure. Locate propane/LP supply tank(s) outdoors

(propane/LP units only). 

3. If you smell gas

• shut off gas supply

• do not try to light any appliance

•  do not touch any electrical switch; do not use any

phone in your building

• immediately call your gas supplier from a neighbor’s

phone. Follow the gas supplier’s instructions

• if you cannot reach your gas supplier, call the

department

4. This appliance shall not be installed in a bedroom or

bathroom.

5. Do not use this appliance as a wood-burning

fireplace. 

Use only the logs provided with the appliance.

6. Do not add extra logs or ornaments such as pine cones,

vermiculite or rock wool. Using these added items can

cause sooting and poor combustion.

7. This appliance is designed to be smokeless. If logs ever

appear to smoke, turn off appliance and call a quali

ed

service person. Note: During initial operation, slight

smoking could occur due to log curing and

fireplace 

burning manufacturing residues. 

8. To prevent the creation of soot, follow the instructions

in

Cleaning and Maintenance

 section.

Keep the appliance area clear and free from

combustible materials, gasoline and other

flamma

ble vapors and liquids.

9. Before using furniture polish, wax, carpet cleaner, or

similar products, turn heater off. If heated, the vapors

from these products may create a white powder residue

within burner box or on adjacent walls or furniture.

10. This appliance needs fresh air ventilation to run prop-

erly. This appliance has an Oxygen Depletion Sensing

(ODS) safety shutoff system. The ODS shuts down the

If appliance keeps shutting off, see

Troubleshooting,

pages 18 through 21.

11. Do not run appliance

•  where flammable liquids or vapors are used or

stored

• under dusty conditions

12. Do not use this appliance to cook food or burn paper

or other objects.

13. Never place any objects in the heater or on logs.
14. Do not use appliance if any part has been under water.

Immediately call a

qualified

service technician to in- 

   spect the room heater and to replace any part of the

control system and any gas control which has been 

15. Turn appliance off and let cool before servicing. Only

a

qualified

service person should service and repair

appliance.

16. Operating appliance above elevations of 4,500 feet

could cause pilot outage. 

17. To prevent performance problems, do not use propane/

LP fuel tanks of less than 100 lbs. capacity.

18. Provide adequate clearances around air openings. 

LOCAL CODES

Install and use appliance with care. Follow all local codes.

In the absence of local codes, use the latest edition of The

National Fuel Gas Code ANSI Z223.1/NFPA 54*.
*Available from:

American National Standards Institute, Inc.

1430 Broadway 

New York, NY  10018

National Fire Protection Association, Inc. 

Batterymarch Park 

Quincy, MA  02269

State of Massachusetts: The installation must

be made by a licensed plumber or gas

fitter

in the

Commonwealth of Massachusetts.
Sellers of unvented propane or natural

gas-fi

red

supplemental room heaters shall provide to each

purchaser a copy of 527 CMR 30 upon sale of

the unit.
Vent-freegasproductsareprohibitedforbedroom

andbathroominstallationintheCommonwealthof

Massachusetts.

Keeptheapplianceareaclearandfreefrom

combustiblematerials,gasoline,andother

flammable vapors and liquids.

SAFETY INFORMATION

CONTINUED

under water.

fireplace

if not enough fresh air is available. See

Air

for Combustion and Ventilation

, pages 4 through 6.

Содержание RIVERSIDE OVT22LP

Страница 1: ...fer to page 4 Air for Combustion and Ventilation INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference This appliance may be installed in an aftermarket perma...

Страница 2: ...low directlyintotheappliance Avoidanydrafts that alter burner ame patterns Ceiling fans can create drafts that alter burner amepatterns Alteredburnerpatternscan cause sooting WARNING Do not use a blow...

Страница 3: ...safety shutoff system The ODS shuts down the If appliance keeps shutting off see Troubleshooting pages 18 through 21 11 Do not run appliance where flammable liquids or vapors are used or stored under...

Страница 4: ...hermostat controlled models have a thermostat sensing bulb and a control valve The thermostat will automatically modulate the heat output to maintain a consistent room temperature This results in grea...

Страница 5: ...s one within 12 of the ceiling and one within 12 of the oor Connect these items directly to the outdoors or spaces open to the s e c a p s l w a r c d n a s c i t t a e d u l c n i s e c a p s e s e h...

Страница 6: ...om the outdoors and vents to the outdoors Example Vent free log set ______________ Btu Hr Gas water heater _____________ Btu Hr Total ________ Btu Hr 4 Compare the maximum Btu Hr the space can support...

Страница 7: ...use mildew to form tilation page 4 CHECK GASTYPE Use the correct gas type natural or propane LP for your appliance If your gas supply is not correct or if you do not know your gas type do not install...

Страница 8: ...he installer must supply an external regulator The external regulator will reduce incoming gas pressure Youmustreduceincominggaspressuretobetween 11 and 14 of water If you do not reduce incoming gas p...

Страница 9: ...d that you install a sediment trap in supply line as shown in Figure 5 Locate sediment trap where it is within reach for cleaning Install in piping system between fuel supply and appliance Locate sedi...

Страница 10: ...r of natural gas or using compressed air 3 Check all joints from gas meter to equipment shutoff valve for natural gas or propane LP supply to equipment shutoff valve for propane LP Apply noncorrosive...

Страница 11: ...LOG PLACEMENT 18 RIVERSIDE OAK LOGS 11...

Страница 12: ...LOG PLACEMENT 24 RIVERSIDE OAK LOGS 12...

Страница 13: ...LOG PLACEMENT OVT22 13...

Страница 14: ...h the chimney damper closed This will put all the heat into the room However there may be times you will desire the full flames of the HI heat setting but will find the heat output excessive You can o...

Страница 15: ...e room temperature drops to a lower than ideal comfort level before the log set comes back on you may want to reposition the thermostat sensing bulb The thermostat sensing bulb is located near the gas...

Страница 16: ...ition with the Capillary at the Bottom OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB Check pilot ame pattern and burner ame patterns of ten INSPECTING BURNERS PILOT FLAME PATTERN Figure 15 shows a c...

Страница 17: ...nd that you keep the burner tube and pilot assembly clean and free of dust and dirt To clean these parts we recommend using compressed air no greater than 30 PSI Your local computer store hardware sto...

Страница 18: ...ure 20 ODS Pilot Air Inlet Hole TROUBLESHOOTING WARNING Turn off log set and let cool before servic ing Only a quali ed service person should service and repair appliance CAUTION Never use a wire need...

Страница 19: ...ere is a spark at ODS Pilot but no ignition OBSERVED PROBLEM ODS pilot lights but ame goes out when control knob is released POSSIBLE CAUSE 1 Control knob not fully pressed in 2 Control knob not press...

Страница 20: ...one Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department IMPORTANT Operating appliance where impurities in air exist may create odors Cleaning supplies...

Страница 21: ...g type of gas used propane LP or natural gas purchase date Usually we will ask you to return the part to the factory Parts Not Under Warranty Contact authorized dealers of this product If they can t s...

Страница 22: ...upport Clip 2 FCHD1809008 FCHD1809008 7 Piezo Igniter with nut 1 RMH 120 90945 RMH 120 90945 8 Gas Valve T Stat NG 1 FCBF09031NG FCBF09031NG 8 Gas Valve T Stat LP 1 FCBF09031LP FCBF09031LP 9 Adapter 3...

Страница 23: ...NOTES 23...

Страница 24: ...rust or discoloring of any kind use or installation contrary to instructions and applicable building codes including heating the product to temperatures above its rated speci cations which can cause c...

Отзывы: