4
1. Remove the carton and log wrap.
2. Remove all protective packaging applied to heater for
shipment.
3. Make sure your logset includes one hardware packet.
4. Check heater for any shipping damage. If h eater is
damaged, call SHM International at (800) 229-5647
for replacement parts before returning to dealer.
UNPACKING
PRODUCT FEATURES
AIR FOR COMBUSTION
AND VENTILATION
Today’s homes are built more energy efficient
than
ever.
New
materials, increased insulation, and new construction methods
help reduce heat loss in homes. Home owners weather strip
and caulk around windows and doors to keep the cold air out
and the warm air in. During heating months, home owners
want their homes as airtight as possible.
While it is good to make your home energy
efficient,
your
home needs to breathe. Fresh air must enter your home. All
fuel-burning appliances need fresh air for proper combus-
tion and ventilation.
Exhaust fans,
fi
replaces, clothes dryers, and fuel burning ap-
pliances draw air from the house to operate. You must provide
adequate fresh air for these appliances. This will insure proper
venting of vented fuel-burning appliances.
SAFETY PILOT
This heater has a pilot with an Oxygen Depletion Sensing
(ODS) safety shutoff system. The ODS/pilot is a required
feature for vent-free room heaters. The ODS/pilot shuts off
the heater if there is not enough fresh air.
PIEZO IGNITION SYSTEM
This heater has a piezo ignitor. This system requires no
matches, batteries or other sources to light heater.
THERMOSTATIC HEAT CONTROL
Thermostat-controlled models have a thermostat sensing
bulb and a control valve. The thermostat will automatically
modulate the heat output to maintain a consistent room
temperature. This results in greater heater comfort. This
can also result in lower gas bills.
WARNING: This heater shall not be
installed in a room or space unless the
required volume of indoor combustion air
is provided by the method described in
the National Fuel Gas Code, ANSI Z223.1/
NFPA 54, the International Fuel Gas Code,
or applicable local codes.
Read the following instructions to insure
proper fresh air for this and other fuel-
burning appliances in your home.
QUALIFIED
INSTALLATION AGENCY
Installation and replacement of gas piping, gas utiliza-
tion equipment or accessories and repair and servicing of
equipment shall be performed only by a
qualified
agency.
The term
“qualified
agency” means any individual,
firm,
corporation, or company that either in person or through a
representative is engaged in and is responsible for:
A. Installation, testing or replacements of gas piping or
B. Connection, installation, testing, repair or servicing
of equipment that is experienced in such work; that
is familiar with all precautions required; and that has
complied with all requirement of the authority having
jurisdiction.
SPECIFICATIONS
(BURNERS)
MODEL
GAS TYPE
INPUT MAX
INPUT MIN
MANIFOLD
INLET MIN
INLET MAX
BVFT18NG
NATURAL
34,000 BTUH
22,000 BTUH
3.5” W.C.
7” W.C
10.5” W.C.
BVFT(22/24)NG
NATURAL
34,000 BTUH
22,000 BTUH
3.5” W.C.
7” W.C
10.5” W.C.
MODEL
GAS TYPE
INPUT MAX
INPUT MIN
MANIFOLD
INLET MIN
INLET MAX
BVFT18LP
LP GAS
34,000 BTUH
22,000 BTUH
10” W.C.
11” W.C
14” W.C.
BVFT(22/24)LP
LP GAS
34,000 BTUH
22,000 BTUH
10” W.C.
11” W.C
14” W.C.
Содержание RIVERSIDE OVT22LP
Страница 11: ...LOG PLACEMENT 18 RIVERSIDE OAK LOGS 11...
Страница 12: ...LOG PLACEMENT 24 RIVERSIDE OAK LOGS 12...
Страница 13: ...LOG PLACEMENT OVT22 13...
Страница 23: ...NOTES 23...