background image

4

1.  Remove the carton and log wrap.

2.  Remove all protective packaging applied to heater for 

shipment.

3.  Make sure your logset includes one hardware packet.

4.  Check  heater  for  any  shipping  damage.  If  h eater  is 

damaged, call SHM International at (800) 229-5647 
for replacement parts before returning to dealer. 

UNPACKING

PRODUCT FEATURES

AIR FOR COMBUSTION 

AND VENTILATION

Today’s homes are built more energy efficient

 

  than

  ever.

  New 

materials, increased insulation, and new construction methods 
help reduce heat loss in homes. Home owners weather strip 
and caulk around windows and doors to keep the cold air out 
and the warm air in. During heating months, home owners 
want their homes as airtight as possible.

While it is good to make your home energy 

efficient,

 your 

home needs to breathe. Fresh air must enter your home. All 
fuel-burning appliances need fresh air for proper combus-
tion and ventilation.

Exhaust fans, 

replaces, clothes dryers, and fuel burning ap-

pliances draw air from the house to operate. You must provide 
adequate fresh air for these appliances. This will insure proper 
venting of vented fuel-burning appliances.

SAFETY PILOT

This heater has a pilot with an Oxygen Depletion Sensing 
(ODS) safety shutoff system. The ODS/pilot is a required 
feature for vent-free room heaters. The ODS/pilot shuts off 
the heater if there is not enough fresh air. 

PIEZO IGNITION SYSTEM

This  heater  has  a  piezo  ignitor.  This  system  requires  no 
matches, batteries or other sources to light heater. 

THERMOSTATIC HEAT CONTROL

Thermostat-controlled  models  have  a  thermostat  sensing 
bulb and a control valve. The thermostat will automatically 
modulate  the  heat  output  to  maintain  a  consistent  room 
temperature.  This  results  in  greater  heater  comfort.  This 
can also result in lower gas bills. 

  WARNING:  This  heater  shall  not  be 

installed  in  a  room  or  space  unless  the 
required volume of indoor combustion air 
is  provided  by  the  method  described  in 
the National Fuel Gas Code, ANSI Z223.1/
NFPA 54, the International Fuel Gas Code, 
or applicable local codes.

Read the following instructions to insure 
proper  fresh  air  for  this  and  other  fuel-
burning appliances in your home. 

QUALIFIED 

INSTALLATION AGENCY

Installation  and  replacement  of  gas  piping,  gas  utiliza-
tion equipment or accessories and repair and servicing of 
equipment shall be performed only by a 

qualified

 agency. 

The term 

“qualified

 agency” means any individual, 

firm, 

corporation, or company that either in person or through a 
representative is engaged in and is responsible for:

A.  Installation, testing or replacements of gas piping or

B.  Connection,  installation,  testing,  repair  or  servicing 

of  equipment  that  is  experienced  in  such  work;  that 
is familiar with all precautions required; and that has 
complied with all requirement of the authority having 
jurisdiction. 

SPECIFICATIONS 

(BURNERS)

MODEL

GAS TYPE
INPUT MAX
INPUT MIN
MANIFOLD 
INLET MIN
INLET MAX

BVFT18NG

NATURAL
34,000 BTUH
22,000 BTUH
3.5” W.C.
7” W.C
10.5” W.C.

BVFT(22/24)NG

NATURAL
34,000 BTUH
22,000 BTUH
3.5” W.C.
7” W.C
10.5” W.C.

MODEL

GAS TYPE
INPUT MAX
INPUT MIN
MANIFOLD 
INLET MIN
INLET MAX

BVFT18LP

LP GAS
34,000 BTUH
22,000 BTUH
10” W.C.
11” W.C
14” W.C.

BVFT(22/24)LP

LP GAS
34,000 BTUH
22,000 BTUH
10” W.C.
11” W.C
14” W.C.

Содержание RIVERSIDE OVT22LP

Страница 1: ...fer to page 4 Air for Combustion and Ventilation INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference This appliance may be installed in an aftermarket perma...

Страница 2: ...low directlyintotheappliance Avoidanydrafts that alter burner ame patterns Ceiling fans can create drafts that alter burner amepatterns Alteredburnerpatternscan cause sooting WARNING Do not use a blow...

Страница 3: ...safety shutoff system The ODS shuts down the If appliance keeps shutting off see Troubleshooting pages 18 through 21 11 Do not run appliance where flammable liquids or vapors are used or stored under...

Страница 4: ...hermostat controlled models have a thermostat sensing bulb and a control valve The thermostat will automatically modulate the heat output to maintain a consistent room temperature This results in grea...

Страница 5: ...s one within 12 of the ceiling and one within 12 of the oor Connect these items directly to the outdoors or spaces open to the s e c a p s l w a r c d n a s c i t t a e d u l c n i s e c a p s e s e h...

Страница 6: ...om the outdoors and vents to the outdoors Example Vent free log set ______________ Btu Hr Gas water heater _____________ Btu Hr Total ________ Btu Hr 4 Compare the maximum Btu Hr the space can support...

Страница 7: ...use mildew to form tilation page 4 CHECK GASTYPE Use the correct gas type natural or propane LP for your appliance If your gas supply is not correct or if you do not know your gas type do not install...

Страница 8: ...he installer must supply an external regulator The external regulator will reduce incoming gas pressure Youmustreduceincominggaspressuretobetween 11 and 14 of water If you do not reduce incoming gas p...

Страница 9: ...d that you install a sediment trap in supply line as shown in Figure 5 Locate sediment trap where it is within reach for cleaning Install in piping system between fuel supply and appliance Locate sedi...

Страница 10: ...r of natural gas or using compressed air 3 Check all joints from gas meter to equipment shutoff valve for natural gas or propane LP supply to equipment shutoff valve for propane LP Apply noncorrosive...

Страница 11: ...LOG PLACEMENT 18 RIVERSIDE OAK LOGS 11...

Страница 12: ...LOG PLACEMENT 24 RIVERSIDE OAK LOGS 12...

Страница 13: ...LOG PLACEMENT OVT22 13...

Страница 14: ...h the chimney damper closed This will put all the heat into the room However there may be times you will desire the full flames of the HI heat setting but will find the heat output excessive You can o...

Страница 15: ...e room temperature drops to a lower than ideal comfort level before the log set comes back on you may want to reposition the thermostat sensing bulb The thermostat sensing bulb is located near the gas...

Страница 16: ...ition with the Capillary at the Bottom OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB Check pilot ame pattern and burner ame patterns of ten INSPECTING BURNERS PILOT FLAME PATTERN Figure 15 shows a c...

Страница 17: ...nd that you keep the burner tube and pilot assembly clean and free of dust and dirt To clean these parts we recommend using compressed air no greater than 30 PSI Your local computer store hardware sto...

Страница 18: ...ure 20 ODS Pilot Air Inlet Hole TROUBLESHOOTING WARNING Turn off log set and let cool before servic ing Only a quali ed service person should service and repair appliance CAUTION Never use a wire need...

Страница 19: ...ere is a spark at ODS Pilot but no ignition OBSERVED PROBLEM ODS pilot lights but ame goes out when control knob is released POSSIBLE CAUSE 1 Control knob not fully pressed in 2 Control knob not press...

Страница 20: ...one Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department IMPORTANT Operating appliance where impurities in air exist may create odors Cleaning supplies...

Страница 21: ...g type of gas used propane LP or natural gas purchase date Usually we will ask you to return the part to the factory Parts Not Under Warranty Contact authorized dealers of this product If they can t s...

Страница 22: ...upport Clip 2 FCHD1809008 FCHD1809008 7 Piezo Igniter with nut 1 RMH 120 90945 RMH 120 90945 8 Gas Valve T Stat NG 1 FCBF09031NG FCBF09031NG 8 Gas Valve T Stat LP 1 FCBF09031LP FCBF09031LP 9 Adapter 3...

Страница 23: ...NOTES 23...

Страница 24: ...rust or discoloring of any kind use or installation contrary to instructions and applicable building codes including heating the product to temperatures above its rated speci cations which can cause c...

Отзывы: