OPERATING LOG SET
Continued
1. Follow steps 1 through 5 under
Lighting
instruction, page 14.
2. Depress control knob and light ODS pilot with match.
3. Keep control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release control knob. Now follow
step 8 under
Lighting
instruction, page 14.
THERMOSTAT
CONTROL OPERATION
The thermostat control knob can be set to any comfort level
between HI and LO. The thermostat will gradually modulate
the heat output and flame height from higher to lower settings,
or pilot, in order to maintain the comfort level you select. The
idealcomfortsettingwillvarybyhouseholddependinguponthe
amount of space to be heated, the output of the central heating
system, etc.
Note: Selecting the HI setting with the control knob will cause
the burners to remain fully on, without modulating down in
most cases.
MANUAL LIGHTING
PROCEDURE
Figure 8-ODS Pilot
Note: The thermostat sensing bulb measures the temperature
of air near the gas control. This may not always agree with
room temperature (depending on housing construction,
installation location, room size, open air temperatures, etc.)
Frequent use of your heater will let you determine your own
comfort levels.
15
Shutting OFF Heater
Turn control knob clockwise
1.
to the
OFF position.
Shutting OFF Burner Only (pilot stays lit)
Turn control knob clockwise
1.
to the
PILOT position.
TO TURN OFF GAS
TO APPLIANCE
OPTIONAL POSITIONING OF
THERMOSTAT SENSING BULB
For Masonry and Factory-built Metal Fireplace
If your log set cycles to pilot, but the room temperature drops to a
lower than ideal comfort level before the log set comes back on, you
may want to reposition the thermostat sensing bulb.
The thermostat sensing bulb is located near the gas valve assembly
onthemountingbracket.Thislocationallowsthethermostattokeep
the room temperature at an ideal comfort level for most fireplace
applications. For positioning the thermostat sensing bulb else-
where, an adhesive-backed mounting clip is available.
1. Remove logs. Locate the gas valve assembly and thermostat
sensing bulb (see Figure 9).
2. Carefully slide the thermostat sensing bulb out of the retaining
clamp (see Figure 10).
IMPORTANT:
Do not force or bend the thermostat sensing
bulb or capillary.
3. The thermostat sensing bulb may be located to the lower right
front side of fireplace. Determine location of sensing bulb, but
do not mount sensing bulb until step 5. If you have a masonry
fireplace, see Figure 11 for location. If you have a factory-
built metal fireplace, see Figure 12 for location. If your fire-
place has glass doors, position sensing bulb directly behind
door gap on right bottom side (see Figure 13).
4. The mounting clip must be a minimum of 3" from bottom of
fireplace to prevent crimping of capillary. Once you have de-
cided on a location, clean the area thoroughly. Remove the pa-
per backing from the adhesive on back of mounting clip. Press
the clip into the new location so that the thermostat sensing bulb
will be positioned vertically with the capillary at the bottom
(see Figure 14). Slide the thermostat sensing bulb into the clip.
IMPORTANT:
Do not crimp capillary.
Thermostat
Sensing Bulb
Figure 9 - Location of Gas Valve Assembly and Thermostat
Sensing Bulb
Gas Valve
Assembly
MountingBracket