Spin Up Device
On an edge detect from 0 to 1, set this item to allow the sSATA device installed on the
sSATA port specified by the user to start a COMRESET initialization. The options are
Enable and
Disable
.
sSATA Device Type
Use this item to specify if the device installed on the sSATA port specified by the user
should be connected to a Solid State drive or a Hard Disk Drive. The options are
Hard
Disk Drive
and Solid State Drive.
PCIe/PCI/PnP Configuration
The following PCI information will be displayed:
PCI Bus Driver Version
PCI Devices Common Settings:
Above 4G Decoding (Available if the system supports 64-bit PCI decoding)
Select Enabled to decode a PCI device that supports 64-bit in the space above 4G Address.
The options are
Enabled
and Disabled.
SR-IOV Support (Available if the system supports Single-Root Virtualization)
Select Enabled for Single-Root IO Virtualization support. The options are Enabled and
Disabled.
MMIO High Base
Use this feature to select the base memory size according to memory-address mapping for
the IO hub. The options are
56T
, 40T, 24T, 16T, 4T, and 1T.
MMIO High Granularity Size
Use this feature to select the high memory size according to memory-address mapping for
the IO hub. The options are 1G, 4G, 16G, 64G,
256G
, and 1024G.
PCI PERR/SERR Support
Use this feature to enable or disable the runtime event for SERR (System Error)/ PERR (PCI/
PCI-E Parity Error). The options are Disabled and
Enabled
.
Maximum Read Request
Select Auto for the system BIOS to automatically set the maximum size for a read request
for a PCI-E device to enhance system performance. The options are
Auto
, 128 Bytes, 256
Bytes, 512 Bytes, 1024 Bytes, 2048 Bytes, and 4096 Bytes.
Содержание SuperServer 8049U-E1CR4T
Страница 1: ...USER S MANUAL Revision 1 0a SuperServer 8049U E1CR4T...
Страница 31: ...31 Chapter 3 Maintenance and Component Installation Figure 3 1 Removing the Chassis Covers Release Tabs...
Страница 54: ...SuperServer 8049U E1CR4T User s Manual 54 Figure 3 13 Installing the PWS Air Shroud...
Страница 60: ...SuperServer 8049U E1CR4T User s Manual 60 Figure 3 20 Left Expansion Card Housing Locking Latches...
Страница 61: ...61 Chapter 3 Maintenance and Component Installation Figure 3 21 Riser RSC R2USW 4E8 and Expansion Cards...
Страница 157: ...Appendix G BSMI Chinese Safety Warnings 157 WARNINGS 1 100V 240V 10 2 3 4 1 2 3 4 5 1 2 3 4...
Страница 158: ...158 1 2 1 2 3 4 SuperServer 8049U E1CR4T User s Manual...
Страница 160: ...160 SuperServer 8049U E1CR4T User s Manual 100 127V 60 50Hz 12 0A 200 240V 60 50Hz 9 6A...