SuperServer 8049U-E1CR4T User's Manual
16
Chapter 2
Server Installation
2.1 Overview
This chapter provides advice and instructions for mounting your system in a server rack.
If your system is not already fully integrated with processors, system memory etc., refer to
Chapter 4 for details on installing those specific components.
Caution:
Electrostatic Discharge (ESD) can damage electronic components. To prevent such
damage to PCBs (printed circuit boards), it is important to use a grounded wrist strap, handle
all PCBs by their edges and keep them in anti-static bags when not in use.
2.2 Preparing for Setup
The box in which the system was shipped should include the rackmount hardware needed to
install it into the rack. Please read this section in its entirety before you begin the installation.
Choosing a Setup Location
•
The system should be situated in a clean, dust-free area that is well ventilated. Avoid areas
where heat, electrical noise, and electromagnetic fields are generated.
•
Leave at least 25 inches of clearance in front of the rack so that you can open the front
door completely. Leave approximately 30 inches of clearance behind the rack to allow suf-
ficient space for airflow and access when servicing.
•
This product should be installed only in a Restricted Access Location (dedicated equipment
rooms, service closets, etc.).
•
This product is not suitable for use with visual display workplace devices according to §2
of the German Ordinance for Work with Visual Display Units.
Rack Precautions
•
Verify that the leveling jacks on the bottom of the rack are extended to the floor so that
the full weight of the rack rests on them.
•
In single rack installations, stabilizers should be attached to the rack. In multiple rack in-
stallations, the racks should be coupled together.
Содержание SuperServer 8049U-E1CR4T
Страница 1: ...USER S MANUAL Revision 1 0a SuperServer 8049U E1CR4T...
Страница 31: ...31 Chapter 3 Maintenance and Component Installation Figure 3 1 Removing the Chassis Covers Release Tabs...
Страница 54: ...SuperServer 8049U E1CR4T User s Manual 54 Figure 3 13 Installing the PWS Air Shroud...
Страница 60: ...SuperServer 8049U E1CR4T User s Manual 60 Figure 3 20 Left Expansion Card Housing Locking Latches...
Страница 61: ...61 Chapter 3 Maintenance and Component Installation Figure 3 21 Riser RSC R2USW 4E8 and Expansion Cards...
Страница 157: ...Appendix G BSMI Chinese Safety Warnings 157 WARNINGS 1 100V 240V 10 2 3 4 1 2 3 4 5 1 2 3 4...
Страница 158: ...158 1 2 1 2 3 4 SuperServer 8049U E1CR4T User s Manual...
Страница 160: ...160 SuperServer 8049U E1CR4T User s Manual 100 127V 60 50Hz 12 0A 200 240V 60 50Hz 9 6A...