SuperServer 8049U-E1CR4T User's Manual
92
PCI-E Completion Timeout Value
This feature allows the user to set the PCI-E Completion Timeout value. The default setting
is
260ms to 900ms
.
Sck3 (Socket 3) RP (Root-Port) Correctable Err (Errors)
Select Enable to enable interrupt on correctable errors occur on a root port. The default
setting is
Disable
.
Sck3 (Socket 3) RP (Root-Port) NonFatal Uncorrectable Err (Errors)
Select Enable to enable interrupt on non-fatal, un-correctable errors occur on a root port.
The default setting is
Disable
.
Sck3 (Socket 3) RP (Root-Port) Fatal Uncorrectable Err (Errors)
Select Enable to enable interrupt on fatal un-correctable errors occur on a root port. The
default setting is
Disable
.
IOAT Configuration
Sck2 (Socket 2) IOAT Configuration/Sck2 (Socket 2) IOAT
Configuration
DCA
Select Enable to enable DAC support. The default setting is
Disable
.
DMA (Direct Memory Access)
Select Enable to enable DMA support. The default setting is
Enable
.
No Snoop
Select Enable to enable No Snoop support. The default setting is
Disable
.
Disable TPH (TLP Processing Hint)
TPH is used for data-tagging with a destination ID and a few important attributes. It can
send critical data to a particular cache without writing through to memory. Select No in this
item for TLP Processing Hint support, which will allow a "TPL request" to provide "hints"
to help optimize the processing of each transaction occurred in the target memory space.
The options are Yes and
No
.
Prioritize TPH (TLP Processing Hint)
Select Yes to prioritize the TPL requests that will allow the "hints" to be sent to help facilitate
and optimize the processing of certain transactions in the system memory. The options are
Enable and
Disable
.
Содержание SuperServer 8049U-E1CR4T
Страница 1: ...USER S MANUAL Revision 1 0a SuperServer 8049U E1CR4T...
Страница 31: ...31 Chapter 3 Maintenance and Component Installation Figure 3 1 Removing the Chassis Covers Release Tabs...
Страница 54: ...SuperServer 8049U E1CR4T User s Manual 54 Figure 3 13 Installing the PWS Air Shroud...
Страница 60: ...SuperServer 8049U E1CR4T User s Manual 60 Figure 3 20 Left Expansion Card Housing Locking Latches...
Страница 61: ...61 Chapter 3 Maintenance and Component Installation Figure 3 21 Riser RSC R2USW 4E8 and Expansion Cards...
Страница 157: ...Appendix G BSMI Chinese Safety Warnings 157 WARNINGS 1 100V 240V 10 2 3 4 1 2 3 4 5 1 2 3 4...
Страница 158: ...158 1 2 1 2 3 4 SuperServer 8049U E1CR4T User s Manual...
Страница 160: ...160 SuperServer 8049U E1CR4T User s Manual 100 127V 60 50Hz 12 0A 200 240V 60 50Hz 9 6A...