5-20
SUPERSERVER 8048B-TR3F/C0R3FT User's Manual
Reset Button
The Reset Button connection is located
on pins 3 and 4 of JF1. Attach it to a
hardware reset switch on the computer
case. Refer to the table on the right for
pin de
fi
nitions.
Reset Button
Pin Defi nitions (JF1)
Pin# De
fi
nition
3
Reset
4
Ground
Overheat (OH)/Fan Fail/PWR Fail/
UID LED
Connect an LED cable to pins 7
and 8 of JF1 to use the Overheat/
Fan Fail/Power Fail and UID LED
connections. The red LED on pin 8
provides warnings for overheating, fan
failure or power failure. The blue LED
on pin 7 works as the front panel UID
LED indicator. Refer to the table on the
right for pin de
fi
nitions.
OH/Fan Fail/ PWR Fail/Blue_
UID LED Pin Defi nitions (JF1)
Pin# De
fi
nition
7
Blue_UID LED
8
OH/Fan Fail/Power Fail
OH/Fan Fail/PWR Fail
LED Status (Red LED)
State De
fi
nition
Off
Normal
On
Overheat
Flashing
Fan Fail
Power Fail LED
The Power Fail LED connection is
located on pins 5 and 6 of JF1. Refer to
the table on the right for pin de
fi
nitions.
PWR Fail LED
Pin Defi nitions (JF1)
Pin# De
fi
nition
5
3.3V
6
PWR Supply Fail
NIC1/NIC2 LED Indicators
The NIC (Network Interface Controller)
LED connection for LAN port 1 is
located on pins 11 and 12 of JF1, and
the LED connection for LAN port 2 is
on pins 9 and 10. Attach the NIC LED
cables here to display network activity.
Refer to the table on the right for pin
de
fi
nitions.
GLAN1/2 LED
Pin Defi nitions (JF1)
Pin# De
fi
nition
9
NIC 2 Activity LED
10
NIC 2 Link LED
11
NIC 1 Activity LED
12
NIC 1 Link LED
Содержание SUPERSERVER 8048B-C0R3FT
Страница 1: ...SUPERSERVER 8048B TR3F 8048B C0R3FT USER S MANUAL Revision 1 0...