5-14
S
UPER
S
ERVER
6010H
Manual
Reset
The Reset connection is located
on pins 3 and 4 of JF1. This con-
nector attaches to the Reset but-
ton on the control panel, which al-
lows you to reboot the system.
See Table 5-8 for pin definitions
and Figure 5-2 for pin locations.
PWR_ON
The PWR_ON connection is lo-
cated on pins 11 and 13 of JF1.
This connector attaches to the
Power button on the control panel,
which allows you to turn on and
off the power to the system. The
user can also configure this but-
ton to function as a suspend but-
ton. (See the Power Button Mode
setting in BIOS.) To turn off the
power when set to suspend mode,
hold down the power button for at
least 4 seconds. See Table 5-9
for pin definitions and Figure 5-2
for pin locations.
Pin
N u m b e r
1
2
Definition
P W _ O N
G r o u n d
Table 5-9
PWR Button
Pin Definitions
(JF1)
Table 5-8
Reset Button
Pin Definitions
(JF1)
Pin
N u m b e r
3
4
Definition
Reset
G r o u n d
Overheat LED
Pins 7 and 8 of JF1 are for the
Overheat LED, which provides you
with advanced warning of chas-
sis overheating. This LED will also
illuminate if the blower fan fails,
which will cause the chassis tem-
perature to rise. Refer to Table 5-
7 for pin definitions and Figure 5-2
for pin locations.
Table 5-7
Overheat LED
Pin Definitions
(JF1)
Pin
N u m b e r
7
8
Definition
V C C 5 V
Control Pin
Содержание SUPERSERVER 6010H
Страница 1: ...SUPERSERVER 6010H USER SMANUAL Revision 1 1a SUPER...
Страница 10: ...Notes SUPERSERVER 6010H User s Manual x...
Страница 30: ...SUPERSERVER 6010H Manual 3 4 Notes...
Страница 34: ...SUPERSERVER 6010H Manual 4 4 Notes...
Страница 68: ...6 10 SUPERSERVER 6010H Manual Notes...
Страница 106: ...SUPERSERVER 6010L Manual B 10 Notes...
Страница 108: ...SUPERSERVER 6010H Manual C 2 Notes...