Chapter 2: Server Installation
2-9
6. Check all cable connections and airflow:
Make sure all power and data cables are properly connected and not
blocking the airflow. See Section 5-3 for details on cable connections.
Also, check the air seals for damage. The air seals are located under
the blower fan and beneath the frame cross section that separates the
drive bay area from the motherboard area of the chassis.
2-6
Checking the Drive Bay Setup
Next, you should check to make sure the peripheral drives and the SCSI
drives and SCA backplane have been properly installed and all connections
have been made.
1. Accessing the drive bays:
All drives can be accessed from the front of the server. For servicing
the CD-ROM and floppy drives, you will need to remove the top chassis
cover. The SCSI disk drives can be installed and removed from the front
of the chassis without removing the top chassis cover.
2. Installing a CD-ROM and floppy disk drives:
Refer to Section 6-4 if you need to reinstall a CD-ROM and/or floppy disk
drive to the system.
3. Check the SCSI disk drives:
Depending upon your system's configuration, your system may have one
or two SCSI drives already installed. If you need to install SCSI drives,
please refer to Section 6-4.
4. Check the airflow:
Airflow is provided by a 10-cm input fan and one (optional) 4-cm cooling
fan. The system component layout was carefully designed to promote
sufficient airflow through the small 1U rackmount space. Also note that
all power and data cables have been routed in such a way that they do
not block the airflow generated by the fans.
Содержание SUPERSERVER 6010H
Страница 1: ...SUPERSERVER 6010H USER SMANUAL Revision 1 1a SUPER...
Страница 10: ...Notes SUPERSERVER 6010H User s Manual x...
Страница 30: ...SUPERSERVER 6010H Manual 3 4 Notes...
Страница 34: ...SUPERSERVER 6010H Manual 4 4 Notes...
Страница 68: ...6 10 SUPERSERVER 6010H Manual Notes...
Страница 106: ...SUPERSERVER 6010L Manual B 10 Notes...
Страница 108: ...SUPERSERVER 6010H Manual C 2 Notes...