Chapter 5: Advanced Motherboard Setup
5-17
5-9
DIP Switch Settings
DIP Switch 1:
Core/Bus Ratio
A red DIP switch labeled SW1 is
included on the mother-
board. This DIP switch has four
individual switches and is used to
set the CPU core/bus ratio. The
example on the right will show you
which CPU core/bus ratio to use.
After determining the ratio, refer to
Table 5-17 for the correct settings
of DIP switch 1.
C P U C o r e /
B u s R a t i o
4 . 0
4 . 5
5 . 0
5 . 5
6 . 0
6 . 5
7 . 0
7 . 5
8 . 0
8 . 5
9 . 0
S W 1
# 4
O N
O N
O N
O N
O F F
O F F
O F F
O F F
O F F
O F F
O F F
S W 1
# 3
O F F
O F F
O F F
O F F
O N
O N
O N
O N
O F F
O F F
O F F
S W 1
# 1
O N
O F F
O N
O F F
O N
O F F
O N
O F F
O N
O F F
O N
Table 5-17
CPU Core/Bus Ratio Selection
(DIP Switch 1)
S W 1
# 2
O N
O N
O F F
O F F
O N
O N
O F F
O F F
O N
O N
O F F
Core/bus ratio = CPU speed / front
side bus speed. Example: a 550 MHz
CPU running at a 100 MHz FSB
speed:
550 (MHz) / 100 (MHz) = 5.5 (ratio)