background image

USER’S MANUAL 

Revision 1.0a

SuperServer

®

SYS-5039MC-H8TRF

Содержание SuperServer 5039MC-H8TRF

Страница 1: ...USER S MANUAL Revision 1 0a SuperServer SYS 5039MC H8TRF...

Страница 2: ...lass A device or in residential environment for Class B device This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s...

Страница 3: ...ivers and utilities https www supermicro com wdl Product safety info http www supermicro com about policies safety_information cfm If you have any questions please contact our support team at support...

Страница 4: ...ning Merchandise for Service 17 Chapter 2 Server Installation 2 1 Overview 18 2 2 Preparing for Setup 18 Choosing a Setup Location 18 Rack Precautions 18 Server Precautions 19 Rack Mounting Considerat...

Страница 5: ...ansion Module 33 Motherboard Battery 34 3 4 Chassis Components 35 Corresponding Nodes Fans and Hard Drives 35 Storage Drives 36 Drive Carrier Indicators 36 Checking the Temperature of an NVMe M 2 Driv...

Страница 6: ...r 6 UEFI BIOS 6 1 Introduction 58 Starting BIOS Setup Utility 58 6 2 Main Setup 58 6 3 Advanced Setup Configurations 60 6 4 IPMI 84 6 5 Security 87 6 6 Event Logs 92 6 7 Boot 94 6 8 Save Exit 96 Appen...

Страница 7: ...om Europe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support sup...

Страница 8: ...FAN 0194L4 4 Air shrouds MCP 310 93805 0B 16 Riser cards RSC RR1U E16 8 Rack mount rails MCP 290 00057 0N 1 set Note A Quick Reference Guide can be found on the SYS 5039MC H8TRF product pages Note Th...

Страница 9: ...s active Memory per node Up to 128GB unbuffered ECC in four DIMM slots with speed of up to DDR4 2666MHz Expansion Slots per node One PCI E 3 0 x8 LP open end slot and one MicroLP slot MicroLP upgradea...

Страница 10: ...n power switch applies or removes primary power from the power supply to the chassis but maintains standby power Node Activity LED Indicators LED Appearance Description Solid Green The node is powered...

Страница 11: ...hows the features included on the front of the chassis Chassis Front Features Item Features Description 1 Control Panel Power buttons and status indicators details on the previous page 2 Storage Drive...

Страница 12: ...Supplies Two redundant power supply modules PWS1 on the left PWS2 on the right 10 IPMI LAN ports Two ports that can be used in two ways Cascade connect the first port to a management device and the s...

Страница 13: ...to a Node USB COM and VGA port capabilities can be added to any node through the KVM port on the rear Plug in the adapter dongle to use these ports Figure 1 5 Adapter to Provide USB COM and VGA Ports...

Страница 14: ...1 SW2 JCPLD1 JKVM1 JUIDB1 JPG1 JPO1 JWD1 J6 JVR1 SRW5 SRW2 SRW3 SRW1 SRW4 MH5 MH3 MH6 MH8 MH7 JPME2 BMC PCI E 3 0 X4 I SATA4 JMD2 M 2 H JMD1 M 2 H PCI E 3 0 X4 I SATA1 2 3 AOC SAS 1 2 ONBOARD SATA J6...

Страница 15: ...PLD1 CPLD code programming JKVM1 VGA COM1 USB Connector on the I O backplane JMD1 JMD2 M 2 Slot JTPM1 Trusted Platform Module Port 80 Connector JPCIE1 CPU PCIE 3 0 x8 Slot JPWR1 12V in ATX Power Conne...

Страница 16: ...s x4 DMI Intel PCH H C246 Socket H4 FLASH SPI 256Mb eSPI eSPI TPM Header RTL8211FS VGA AST2500 PCIe3 0_x1 8 0GT s PCIe x8 MLP SLOT USB3 5 2 X USB 2 0 MLP USB2 0 480Mbps USB2 5 Port 13 Port 21 LPC RGMI...

Страница 17: ...be prominently displayed on the outside of the shipping carton and mailed prepaid or hand carried Shipping and handling charges will be applied for all orders that must be mailed when service is compl...

Страница 18: ...dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated Leave enough clearance in front of the rack so that you can open the front door...

Страница 19: ...in case of a power failure Allow any drives and power supply modules to cool before touching them When not servicing always keep the front door of the rack and all covers panels on the servers closed...

Страница 20: ...pply connections other than the direct connections to the branch circuit i e the use of power strips etc To prevent bodily injury when mounting or servicing this unit in a rack you must take special p...

Страница 21: ...installation instructions that came with the specific rack you are using Identifying the Rails The chassis package includes two rail assemblies Each assembly consists of three sections an inner rail t...

Страница 22: ...ng completely out of the rack when the chassis is pulled out for servicing To mount the rail onto the chassis first release the inner rail from the outer rails 1 Pull the inner rail out of the outer r...

Страница 23: ...st the side of the chassis aligning the hooks on the side of the chassis with the holes in the inner rail 3 Slide the inner rail forward toward the front of the chassis until the quick release bracket...

Страница 24: ...rail adjusting the length until it just fits within the posts of the rack 5 Hang the hooks of the rear section of the outer rail onto the square holes on the rear of the rack Take care that the proper...

Страница 25: ...rails 2 Align the inner rails of the chassis with the outer rails on the rack 3 Slide the inner rails into the outer rails keeping the pressure even on both sides When the chassis has been pushed comp...

Страница 26: ...to remove it from the rack Have sufficient personnel or use a lift to support the chassis 1 Pull the chassis forward out the front of the rack until it stops 2 Press the release latches on each of the...

Страница 27: ...hat power first be removed from the system Please follow the procedures given in each section 3 1 Removing Power Before performing some setup or maintenance tasks use the following procedure to ensure...

Страница 28: ...nue operating Removing a Computing Node The two storage drives controlled by the node will power down upon removal 1 Power down the node using the operating system or the power button 2 Remove any cab...

Страница 29: ...such as fans by removing the cover Removing the Chassis Cover The chassis top cover can be lifted off after removing three screws Caution Except for short periods of time do not operate the server wit...

Страница 30: ...y modules of the same type speed and size will result in interleaved memory which improves performance Check the Supermicro website for possible updates to memory support DIMM Module Population Config...

Страница 31: ...n the following order DIMMB2 DIMMA2 then DIMMB1 and DIMMA1 The blue slots must be populated first DIMMB2 Blue Slot DIMMA2 Blue Slot Towards the edge of the motherboard Towards the CPU DIMMA1 DIMMB1 No...

Страница 32: ...em as described in Section 3 1 Follow the memory population sequence in the table above 1 Push the release tabs outwards on both ends of the DIMM slot to unlock it Notches Release Tabs 2 Align the key...

Страница 33: ...E 3 0 x4 slot with SATA3 support M Key 2280 22110 The MicroLP expansion module is inserted into a riser card and secured to two brackets as shown below This assembly is inserted into the expansion slo...

Страница 34: ...placing the Battery Begin by removing power from the system as described in section 3 1 1 Push aside the small clamp that covers the edge of the battery When the battery is released lift it out of the...

Страница 35: ...age drives and shares a fan with the node beside it If a node is pulled out of the chassis the associated drives will power down Figure 3 5 Corressponding Nodes Fans and Drives Node Fan Drives Node 1...

Страница 36: ...ch as hot spare Drive Carrier LED Indicators Color Blinking Pattern Behavior for Device Activity LED Blue Solid On SAS drive installed Blue Blinking I O activity Status LED Red Solid On Failure of dri...

Страница 37: ...Removing a Hot Swap Drive Carrier from the Chassis 1 Press the release button on the drive carrier which will extend the drive carrier handle 2 Use the drive carrier handle to pull the drive out of t...

Страница 38: ...moving a Hot Swap Drive Carrier from the Chassis 1 Press the release button on the drive carrier which will extend the drive carrier handle 2 Use the drive carrier handle to pull the drive out of the...

Страница 39: ...nnector end toward the rear of the carrier Align the drive in the carrier so that the screw holes line up Note that there are holes in the carrier marked SATA to aid in correct installation 3 Secure t...

Страница 40: ...actor 2280 22110 M 2 Key M Key Installing an M 2 SSD Caution Use industry standard anti static equipment such as gloves or wrist strap and follow precautions to avoid damage caused by ESD Locate the s...

Страница 41: ...e with the same model Failed fans can be identified through the IPMI Changing a System Fan 1 Determine which fan has failed using IPMI or if necessary open the chassis while the system is running Neve...

Страница 42: ...ze fan efficiency Air block is pre installed and may be uninstalled by removing the two screws Installing the Air Shroud 1 Power down the node and remove it If an expansion card is used install it fir...

Страница 43: ...240v An amber light will be illuminated on the power supply when the power is off An illuminated green light indicates that the power supply is operating Changing the Power Supply 1 With the system ru...

Страница 44: ...ket to the motherboard tray 3 Remove the PCI slot bracket 4 Remove the PCI slot shield PCI Slot Shield Figure 3 13 PCI Expansion Card Chassis Slots 5 Insert the expansion card into the riser card whic...

Страница 45: ...45 Chapter 3 Maintenance and Component Installation Expansion Card PCI Slot Bracket Node Motherboard Tray Screws Figure 3 14 Installing an Expansion Card Chassis Slots...

Страница 46: ...provide power to the motherboard Power Connector Pin Definitions Pin Definition 1 Ground 2 P12V 4 2 Headers and Connectors TPM Header The JTPM1 header is used to connect a Trusted Platform Module TPM...

Страница 47: ...as two I SATA 3 0 ports I SATA1 I SATA4 through the backplane that are supported by the Intel C246 chipset Power Switch Press the power switch at SW2 to turn on the motherboard SGPIO Header The S SGPI...

Страница 48: ...se to control multiple computers It also provides a VGA connection COM1 and two USB 2 0 connections USB0 1 COM Port The motherboard has one COM port header to provide a serial connection COM Port Pin...

Страница 49: ...ED Indicator A Unit Identifier UID switch and an LED indicator are located on the motherboard The UID switch is located at JUIDB1 The UID LED is located at LED2 next to the UID button When you press t...

Страница 50: ...ved Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally cle...

Страница 51: ...troller The default setting is Enabled VGA Enable Disable Jumper Settings Jumper Setting Definition Pins 1 2 Enabled Pins 2 3 Disabled Watch Dog JWD1 controls the Watch Dog function Watch Dog is a mon...

Страница 52: ...LED indicator The LED indicator provides easy identification of a system unit that may need service UID LED Pin Definitions Color Status Blue On Unit Identified System Failure LED LED3 is the System...

Страница 53: ...upermicro com support manuals Installing the OS 1 Create a method to access the MS Windows installation ISO file That might be a DVD perhaps using an external USB SATA DVD drive or a USB flash drive o...

Страница 54: ...load the driver browse the USB flash drive for the proper driver files For RAID choose the SATA sSATA RAID driver indicated then choose the storage drive on which you want to install it For non RAID...

Страница 55: ...Another option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard and Download the Latest Drivers and Utilities Insert the flash drive or...

Страница 56: ...s alerts via email or Simple Network Management Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With Supe...

Страница 57: ...ted Multi node information and the system information can be displayed at the same time In IPMI Web GUI view information can be displayed by clicking Multi Node under the Server Health drop down menu...

Страница 58: ...These are blue When an option is selected it is highlighted in white Settings printed in Bold are the default values In the left frame a indicates a submenu Highlighting such an item and pressing the...

Страница 59: ...or the arrow keys to move between fields The date must be entered in MM DD YYYY format The time is entered in HH MM SS format Note The time is in the 24 hour format For example 5 30 P M appears as 17...

Страница 60: ...ot Enable this feature to reduce the time the computer takes to boot up The computer will boot with a minimal set of required devices This feature does not have an effect on BBS boot options in the Bo...

Страница 61: ...bled Restore on AC Power Loss Use this feature to set the power state after a power outage Select Power Off for the system power to remain off after a power loss Select Power On for the system power t...

Страница 62: ...and Enabled If the feature above is set to Enabled CPU Flex Ration Setting will become available for configuration CPU Flex Ratio Settings When CPU Flex Ration override is enabled this feature sets t...

Страница 63: ...y The options are Disabled and Enabled Boot Performance Mode This feature allows the user to select the performance state that the BIOS will set before the operating system handoff The options are Pow...

Страница 64: ...State Un demotion Use this feature to enable or disable the Package C State un demotion The options are Disabled and Enabled CState Pre Wake This feature allows the user to enable or disable the C Sta...

Страница 65: ...ory Configuration Memory RC Version Memory Frequency Memory Timings tCL tRCD tRP tRAS DIMMA1 DIMMA2 DIMMB1 DIMMB2 Maximum Memory Frequency Use this feature to set the maximum memory frequency for onbo...

Страница 66: ...o set the ASPM Active State Power Management state on the SA System Agent side of the DMI Link The options are Disabled L0s L1 and L0sL1 DMI Extended Sync Control Use this feature to enable or disable...

Страница 67: ...able or disable the PCI Express Graphics PEG device in the port specified by the user The options are Disabled Enabled and Auto Max Link Speed Use this feature to select speed for the device installed...

Страница 68: ...If this feature is set to Enabled PCI E ASMP will be programmed after OPROM If set to Disabled the PCI E ASPM will be programmed before OPROM The options are Disabled and Enabled Internal Graphics Sel...

Страница 69: ...stem configuration Select Disabled to disable ASPM support The options are Disabled L0s L1 L0sL1 and Auto JMD1 M 2 H L1 Substates Use this feature to set the PCI Express L1 Substates The options are D...

Страница 70: ...Select Enabled to enable the selected onboard serial port The options are Disabled and Enabled Device Settings This feature displays the status of a serial port specified by the user Change Settings T...

Страница 71: ...ration Console Redirection Settings Terminal Type This feature allows the user to select the target terminal emulation type for Console Redirection Select VT100 to use the ASCII Character set Select V...

Страница 72: ...ion to prevent data loss caused by buffer overflow Send a Stop signal to stop sending data when the receiving buffer is full Send a Start signal to start sending data when the receiving buffer is empt...

Страница 73: ...following features are available for configuration Console Redirection Settings Out of Band Mgmt Port The feature selects a serial port in a client server to be used by the Microsoft Windows Emergenc...

Страница 74: ...gure a SATA drive specified by the user as a RAID drive The options are AHCI and RAID SATA Frozen Use this feature to enable the HDD Security Frozen Mode The options are Enabled and Disabled Aggressiv...

Страница 75: ...ve on the particular SATA port on the JMD1 slot Model number of drive and capacity Software Preserve Support Serial ATA Port 1 Hot Plug Set this feature to Enable for hot plug support which will allow...

Страница 76: ...plays the information detected on the installed SATA drive on the particular SATA port on the JMD2 slot Model number of drive and capacity Software Preserve Support Serial ATA Port 4 Hot Plug Set this...

Страница 77: ...interrupts at a much higher frequency than a Real time Clock RTC does in synchronizing multimedia streams providing smooth playback and reducing the dependency on other timestamp calculation devices s...

Страница 78: ...off The XHCI ownership change should be claimed by the XHCI driver The settings are Enabled and Disabled USB Mass Storage Driver Support Select Enabled for USB mass storage device support The options...

Страница 79: ...3 0 X8 OPROM Use this feature to select which firmware to be loaded for the add on card in this slot The options are Disabled Legacy and EFI CPU SLOT1 PCIE 3 0 X8 OPROM Use this feature to select whic...

Страница 80: ...your keyboard to change the value The default setting is 1 Trusted Computing The features in the Trusted Computing section on this page are displayed if a TPM 1 2 module is detected Firmware Version...

Страница 81: ...rivacy control The options are Disabled and Enabled TPM2 0 UEFI Spec Version Use this feature to specify the TPM UEFI spec version TCG 1 2 has support for Windows 2012 Windows 8 and Windows 10 TCG 2 h...

Страница 82: ...allows the user to enter the unique name of the iSCSI Initiator in IQN format Once the name of the iSCSI Initiator is entered into the system configure the proper settings for the following items Add...

Страница 83: ...input the certification GUID Commit Changes and Exit Use this feature to save all changes and exit TLS settings Discard Changes and Exit Use this feature to discard all changes and exit TLS settings...

Страница 84: ...ng Disabling Options SEL Components Select Enabled for all system event logging at boot up The options are Disabled and Enabled Erasing Settings Erase SEL Select Yes On next reset to erase all system...

Страница 85: ...ink Status This feature displays the IPMI Network Link status The default setting is Dedicated LAN Configuration Address Source Use this feature to select the source of the IP address for this compute...

Страница 86: ...figure IPV6 support IPV6 Support Use this feature to enable IPV6 support The options are Enabled and Disabled Configuration Address Source Use this feature to select the source of the IP address for t...

Страница 87: ...ssword should be from 3 to 20 characters long Password Check Select Setup for the system to check for a password at Setup Select Always for the system to check for a password at bootup or upon enterin...

Страница 88: ...nt Factory Key Provision Select Enabled to install the default Secure Boot keys set by the manufacturer The options are Disabled and Enabled Restore Factory Keys Select Yes to restore all factory keys...

Страница 89: ...Update Select Yes to load a factory default KEK or No to load from a file on an external media Append Select Yes to add the KEK from the manufacturer s defaults list to the existing KEK Select No to l...

Страница 90: ...existing dbx Select No to load the dbx from a file The options are Yes and No Delete Select Ok to remove the dbx and then the system will reset to Setup Audit Mode Authorized TimeStamps Details Selec...

Страница 91: ...n external media Update Select Yes to load a factory default dbr or No to load from a file on an external media Append Select Yes to add the dbr from the manufacturer s defaults list to the existing d...

Страница 92: ...s are Disabled and Enabled Erasing Settings Erase Event Log Select Enabled to erase all error events in the SMBIOS System Management BIOS log before an event logging is initialized at bootup The optio...

Страница 93: ...to 255 The default setting is 1 METW Multiple Event Count Time Window This feature is used to determine how long in minutes should the multiple event counter wait before generating a new event log Ent...

Страница 94: ...ture to specify the length of time the number of seconds for the BIOS to wait before rebooting the system when the setup activation key is pressed Enter the value of 65535 0xFFFF for the BIOS to wait...

Страница 95: ...LEGACY UEFI DUAL Boot Order 9 LEGACY UEFI DUAL Boot Order 10 LEGACY UEFI DUAL Boot Order 11 LEGACY UEFI DUAL Boot Order 12 LEGACY UEFI DUAL Boot Order 13 LEGACY UEFI DUAL Boot Order 14 LEGACY UEFI DU...

Страница 96: ...lect Discard Changes and Exit from the Exit menu and press Enter Save Changes and Reset When you have completed the system configuration changes select this option to save all changes made and reset t...

Страница 97: ...s from the Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore User Defaults from the Exit men...

Страница 98: ...their corresponding beep codes encountered by users BIOS Error Beep POST Codes Beep Code Error Message Description 1 short Refresh Circuits have been reset Ready to power up 5 short 1 long Memory err...

Страница 99: ...for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis Th...

Страница 100: ...po considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontra...

Страница 101: ...erken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aa...

Страница 102: ...mentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het sy...

Страница 103: ...entes del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l in...

Страница 104: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...

Страница 105: ...mkabels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment...

Страница 106: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...

Страница 107: ...so a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc...

Страница 108: ...emblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incor...

Страница 109: ...nt aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All...

Страница 110: ...omloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Atte...

Страница 111: ...Advertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques...

Страница 112: ...cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is...

Страница 113: ...onale elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled acco...

Страница 114: ...recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving...

Страница 115: ...destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient...

Страница 116: ...UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSA Supermicro Supermicro UL CSA UL CSA Supermicro U...

Страница 117: ...sur le code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el producto...

Страница 118: ...Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storin...

Страница 119: ...p to DDR4 2666MHz Storage Drives Two 3 5 SATA3 drives or two 2 5 SATA3 with optional kits PCI Expansion Slots per node One PCI E 3 0 x8 LP open end slot One MicroLP slot MicroLP upgradeable Two PCI E...

Страница 120: ...10 9 8A 50 60Hz 2000W 230 240Vac 10 9 8A 50 60 Hz 2000W 200 240Vac 11 8 9 8A 50 60 Hz UL cUL only 12V Max 83 3A Min 0A 100Vac 127Vac Max 150A Min 0A 200Vac 220Vac Max 165A Min 0A 220Vac 230Vac Max 166...

Страница 121: ...00 4 8 EN BS 61000 4 11 Green Environment 2011 65 EU RoHS Directive EC 1907 2006 REACH 2012 19 EU WEEE Directive California Proposition 65 Product Safety 2014 35 EU LVD Directive UL CSA 60950 1 2nd Ed...

Страница 122: ...mage The recovery block contains critical BIOS codes including memory detection and recovery codes for the user to flash a healthy BIOS image if the original main BIOS image is corrupted When the syst...

Страница 123: ...ifferent machine copy the Super ROM binary image file into the Root directory of a USB device or a writable CD DVD Note 1 If you cannot locate the Super ROM file in your drive disk visit our website a...

Страница 124: ...de if you want to start the BIOS recovery If you decide to proceed with BIOS recovery follow the procedures below 4 When the screen as shown above displays use the arrow keys to select the item Procee...

Страница 125: ...to enter the BIOS Setup utility From the top of the tool bar select Boot to enter the submenu From the submenu list select Boot Option 1 as shown below Then set Boot Option 1 to UEFI AP UEFI Built in...

Страница 126: ...interrupt this process until the BIOS flashing is complete 9 The screen above indicates that the BIOS update process is complete When you see the screen above unplug the AC power cable from the power...

Страница 127: ...ou can download a crash dump of status information using IPMI The IPMI manual is available at https www supermicro com solutions IPMI cfm Check IPMI Error Log 1 Access the IPMI web interface 2 Click t...

Страница 128: ...ystem remains in a failed state Do not check this box until after the dump file has been sent to Support Downloading the Crash Dump File 1 In the IPMI interface click the Miscellaneous tab then the Tr...