6-4 Air Shrouds
Air shrouds concentrate airflow to maximize fan efficiency. The chassis
requires air shrouds for each serverboard node. Air shrouds vary depending upon
the serverboard used. See the illustrations below.
Installing an Air Shroud (Figure 6-3)
1. Make sure that the serverboard expansion card (if applicable) and all
components are properly installed in each serverboard node.
2.
Place the first air shroud pieces in the serverboard, as shown below. The air
shroud sits on either side of the CPUs and DIMM slots.
3. Repeat the procedure for the remaining three serverboard nodes.
6-5 Checking the Airflow
Checking Airflow
1.
Make sure there are no objects obstructing the airflow in and out of the
chassis. In addition, if you are using a front bezel, make sure the bezel's filter
is replaced periodically.
2. Except for brief periods while swapping hard drives, do not operate the server
without drives or the drive carriers in the drive bays. Use only recommended
server parts.
3.
Make sure no wires or foreign objects obstruct airflow through the chassis.
Pull all excess cabling out of the airflow path or use shorter cables.
4. The control panel LEDs inform you of system status. See “Chapter 3: System
Interface” for details on the LEDs and the control panel buttons.
6-6 System Fans
Four fans provide cooling for the chassis. These fans circulate air through the
chassis as a means of lowering the chassis internal temperature. The
system fans are easy to change modules. There is no need to uninstall any
other parts inside the system when replacing fans, and no tools are required for
installation.
Optional Fan Configurations
The model chassis is designed so that the default configuration of
the system is for each serverboard to control two fans. Each serverboard node in
the chassis is connected to the backplane through the adapter card, mounted in
the serverboard node drawer. In the event that one of the serverboard drawers is
removed, then the remaining serverboard will operate both fans.
Default Fan Configuration
Fans A and B connected to backplane,
backplane connected to Node A and B by adapter card
Fans C and D connected to backplane,
backplane connected to Nodes A and B by adapter card
Figure 6-3. Installing the Air Shroud
Note:
the serverboards shown in this chapter are for illustrative purposes only.
Содержание SUPERSERVER 2028TP-HC0R-SIOM
Страница 1: ...USER S MANUAL Revision 1 0 SUPERSERVER 2028TP HTR SIOM 2028TP HC0R SIOM 2028TP HC1R SIOM...
Страница 6: ...x Notes SUPERSERVER 2028TP HTR HC0R HC1R SIOM USER S MANUAL...
Страница 11: ...1 8 SUPERSERVER 2028TP HTR HC0R HC1R SIOM USER S MANUAL Notes...
Страница 19: ...SUPERSERVER 2028TP HTR HC0R HC1R SIOM USER S MANUAL 3 4 Notes...
Страница 43: ...5 24 SUPERSERVER 2028TP HTR HC0R HC1R SIOM USER S MANUAL Notes...
Страница 77: ...A 2 SUPERSERVER 2028TP HTR HC0R HC1R SIOM USER S MANUAL Notes...