Chapter 2: Server Installation
2-5
2-4
SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL
2-5 Installing the System into a Rack
This section provides information on installing the 2028TP-HTR/HC0R/HC1R-SIOM
into a rack unit with the rails provided. There are a variety of rack units on the market,
which may mean that the assembly procedure will differ slightly from the instructions
provided. You should also refer to the installation instructions that came with the
rack unit you are using.
Note:
This rail will fit a rack between 26.5" and 36.4" deep.
Identifying the Sections of the Rack Rails
The chassis package includes two rail assemblies in the rack mounting kit. Each
assembly consists of three sections: An inner chassis rail which secures directly to
the chassis, an outer rail that secures to the rack, and a middle rail which extends
from the outer rail (see Figure 2-1). These assemblies are specifically designed for
the left and right side of the chassis.
Figure 2-1. Identifying the Outer Rail, Middle Rail and Inner Rails
(Left Rail Assembly Shown)
Inner Rail
Rail Assembly
(Shown with Rails
Retracted)
This Side Faces
Outward
Locking Tab
Middle Rail
Outer Rail
Figure 2-2. Extending and Releasing the Inner Rail
Locking Tabs
Each inner rail has a locking tab. This tab locks the chassis into place when installed
and pushed fully into the rack. These tabs also lock the chassis in place when fully
extended from the rack. This prevents the server from coming completely out of
the rack when when the chassis is pulled out for servicing.
Releasing the Inner Rail
Use the procedure below to release the inner rails from the outer rails.
Releasing Inner Rail from the Outer Rails (Figure 2-2)
1. Identify the left and right outer rail assemblies as described in section 2-5.
2. Pull the inner rail out of the outer rail until it is fully extended as illustrated
below.
3. Press the locking tab down to release the inner rail.
4. Pull the inner rail all the way out.
5. Repeat steps 1-3 for the second outer rail.
1
2
1
1
1
3
1
4
Warning:
do not pick up the server with the front handles. They are
designed to pull the system from a rack only.
Содержание SUPERSERVER 2028TP-HC0R-SIOM
Страница 1: ...USER S MANUAL Revision 1 0 SUPERSERVER 2028TP HTR SIOM 2028TP HC0R SIOM 2028TP HC1R SIOM...
Страница 6: ...x Notes SUPERSERVER 2028TP HTR HC0R HC1R SIOM USER S MANUAL...
Страница 11: ...1 8 SUPERSERVER 2028TP HTR HC0R HC1R SIOM USER S MANUAL Notes...
Страница 19: ...SUPERSERVER 2028TP HTR HC0R HC1R SIOM USER S MANUAL 3 4 Notes...
Страница 43: ...5 24 SUPERSERVER 2028TP HTR HC0R HC1R SIOM USER S MANUAL Notes...
Страница 77: ...A 2 SUPERSERVER 2028TP HTR HC0R HC1R SIOM USER S MANUAL Notes...