Chapter 5: Advanced Serverboard Setup
5-7
5-6
SUPERSERVER 2028TP-HTR/HC0R/HC1R-SIOM USER'S MANUAL
8. Make sure the locking mechanism
on the "Close 1st" lever catches
the lip of the load plate. Close and
lock the "Close 1st" lever.
Push down and lock the
lever labeled "Open 1st"
OPEN 1s
t
OPEN 1s
t
Push down and lock the
lever labeled "Close 1st".
9. Close and lock the "Open 1st"
lever.
Engage the lip of
the load plate and
locking portion of
the lever."
7. With the "Close 1st" lever fully
retracted, gently close the load
plate.
Gently close
the load plate.
Installing a Passive CPU Heatsink
1. Do not apply any thermal grease to the heatsink or the CPU die -- the
required amount has already been applied.
2. Place the heatsink on top of the CPU so that the four mounting holes are
aligned with those on the Serverboard's and the Heatsink Bracket underneath.
3. Screw in two diagonal screws (i.e., the #1 and the #2 screws) until just snug
(-do not over-tighten the screws to avoid possible damage to the CPU.)
4. Finish the installation by fully tightening all four screws.
SNK-P0057PS
Screw#1
Screw#2
Screw#3
Screw#4
SNK-P0047PSM
Содержание SUPERSERVER 2028TP-HC0R-SIOM
Страница 1: ...USER S MANUAL Revision 1 0 SUPERSERVER 2028TP HTR SIOM 2028TP HC0R SIOM 2028TP HC1R SIOM...
Страница 6: ...x Notes SUPERSERVER 2028TP HTR HC0R HC1R SIOM USER S MANUAL...
Страница 11: ...1 8 SUPERSERVER 2028TP HTR HC0R HC1R SIOM USER S MANUAL Notes...
Страница 19: ...SUPERSERVER 2028TP HTR HC0R HC1R SIOM USER S MANUAL 3 4 Notes...
Страница 43: ...5 24 SUPERSERVER 2028TP HTR HC0R HC1R SIOM USER S MANUAL Notes...
Страница 77: ...A 2 SUPERSERVER 2028TP HTR HC0R HC1R SIOM USER S MANUAL Notes...