background image

iii

Preface

Preface

About This Manual

This manual is written for professional system integrators and PC technicians. 
It provides information for the installation and use of the SuperServer 
2028TP-HTR/HC0R/HC1R-SIOM. Installation and maintainance should be 
performed by experienced technicians only.
The SuperServer 2028TP-HTR/HC0R/HC1R-SIOM is a high-end server based 
on the  -R2K04BP2 2U rackmount chassis and the dual processor 
X10DRT-PS serverboard. All models have four serverboard nodes with six hot-swap 
Hard Disk Drives (HDD) each per node.

Manual Organization

Chapter 1: Introduction

The  first  chapter  provides  a  checklist  of  the  main  components  included  with  the 

server system and describes the main features of the X10DRT-PS serverboard and 
the -R2K04BP2 chassis.

Chapter 2: Server Installation

This chapter describes the steps necessary to install the SuperServer 

2028TP-HTR/HC0R/HC1R-SIOM into a rack and check out the server configuration 

prior to powering up the system. If your server was ordered without processor and 
memory components, this chapter will refer you to the appropriate sections of the 
manual for their installation.

Chapter 3: System Interface

Refer here for details on the system interface, which includes the functions and 
information provided by the control panel on the chassis as well as other LEDs 
located throughout the system.

Chapter 4: Standardized Safety Warnings

You should thoroughly familiarize yourself with this chapter for a general overview 
of safety precautions that should be followed when installing and servicing the 
SuperServer 2028TP-HTR/HC0R/HC1R-SIOM.

Chapter 5: Advanced Serverboard Setup

Chapter 5 provides detailed information on the X10DRT-PS serverboard, including 
the locations and functions of connections, headers and jumpers. Refer to 
this chapter when adding or removing processors or main memory and when 

reconfiguring the serverboard.

The information in this User’s Manual has been carefully reviewed and is believed to be accurate.  

The vendor assumes no responsibility for any inaccuracies that may be contained in this document, 

makes no commitment to update or to keep current the information in this manual, or to notify any 

person or organization of the updates. 

Please Note: For the most up-to-date version of this 

manual, please see our web site at www.supermicro.com.

Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product 

described in this manual at any time and without notice. This product, including software and 

documentation, is the property of Supermicro and/or its licensors, and is supplied only under a 

license. Any use or reproduction of this product is not allowed, except as expressly permitted by 

the terms of said license.

 IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, 

SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO 

USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF 

SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY 

HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE 

COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH 

HARDWARE, SOFTWARE, OR DATA.

Any disputes arising between manufacturer and customer shall be governed by the laws of Santa 

Clara County in the State of California, USA. The State of California, County of Santa Clara shall 

be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all 

claims will not exceed the price paid for the hardware product.

FCC Statement: This equipment has been tested and found to comply with the limits for a Class 

A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide 

reasonable protection against harmful interference when the equipment is operated in a commercial 

environment. This equipment generates, uses, and can radiate radio frequency energy and, if not 

installed and used in accordance with the manufacturer’s instruction manual, may cause harmful 

interference with radio communications. Operation of this equipment in a residential area is likely 

to cause harmful interference, in which case you will be required to correct the interference at your 

own expense.

California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate 

warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate 

Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”

WARNING: Handling of lead solder materials used in this 

product may expose you to lead, a chemical known to 

the State of California to cause birth defects and other 

reproductive harm.

Manual Revision 1.0 

Release Date: May 12, 2016

Unless you request and receive written permission from Super Micro Computer, Inc., you may not 

copy any part of this document.

Information in this document is subject to change without notice.  Other products and companies 

referred to herein are trademarks or registered trademarks of their respective companies or mark 

holders.

Copyright © 2016 by Super Micro Computer, Inc. 

All rights reserved. 

Printed in the United States of America

Содержание SUPERSERVER 2028TP-HC0R-SIOM

Страница 1: ...USER S MANUAL Revision 1 0 SUPERSERVER 2028TP HTR SIOM 2028TP HC0R SIOM 2028TP HC1R SIOM...

Страница 2: ...This product including software and documentation is the property of Supermicro and or its licensors and is supplied only under a license Any use or reproduction of this product is not allowed except...

Страница 3: ...res given in this chapter when installing removing or reconfiguring hard drives and when replacing system power supply units and cooling fans Chapter 7 BIOS The BIOS chapter includes an introduction t...

Страница 4: ...R SIOM USER S MANUAL vii Locking Tabs 2 5 Releasing the Inner Rail 2 5 Installing The Inner Rails on the Chassis 2 6 Installing the Outer Rails on the Rack 2 7 Standard Chassis Installation 2 8 Chapte...

Страница 5: ...Optional Fan Configurations 6 5 6 7 Removing and Installing the Backplane 6 8 Removing the Backplane 6 8 Installing the Backplane 6 10 6 8 Installing the Serverboard 6 11 I O Shield 6 11 Permanent an...

Страница 6: ...x Notes SUPERSERVER 2028TP HTR HC0R HC1R SIOM USER S MANUAL...

Страница 7: ...PU SNK P0047PSM Four 1U passive CPU heatsinks w narrow ILM SNK P0057PS Four mylar air shrouds MCP 310 21703 0B Four 8 cm cooling fans FAN 0162L4 SATA SAS Backplane Four HD backplanes BPN ADP 6SATA3P B...

Страница 8: ...drives are hot swappable units SATA The 2028TP HTR SIOM uses a controller integrated into the PCH C612 chipset to support six SAS3 hard drives per node RAID 0 1 5 6 10 50 and 60 supported The SATA dri...

Страница 9: ...assis includes one mylar air shroud per node that directs the airflow where cooling is needed on each serverboard Always use the air shroud included with each serverboard Mounting Rails The SC217HQ in...

Страница 10: ...ds act as a separate node in the system As independent nodes each may be powered off and on without affecting the others In addition each node is a hot swappable unit that may be removed from the rear...

Страница 11: ...1 8 SUPERSERVER 2028TP HTR HC0R HC1R SIOM USER S MANUAL Notes...

Страница 12: ...ged in any way If the server itself shows damage you should file a damage claim with the carrier who delivered it Decide on a suitable location for the rack unit that will hold the 2028TP HTR HC0R HC1...

Страница 13: ...nts on the servers closed when not servicing to maintain proper cooling Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi unit rack assembly the ambient oper...

Страница 14: ...gure 2 1 Identifying the Outer Rail Middle Rail and Inner Rails Left Rail Assembly Shown Inner Rail Rail Assembly Shown with Rails Retracted This Side Faces Outward Locking Tab Middle Rail Outer Rail...

Страница 15: ...on the Rack Use the procedure below to install the outer rails onto the rack Installing the Outer Rails Figure 2 5 1 Press upward on the locking tab at the rear end of the middle rail 2 Push the middl...

Страница 16: ...ion of the middle rail 4 Align the chassis inner rails with the front of the middle rails 5 Slide the inner rails on the chassis into the middle rails keeping the pressure even on both sides until the...

Страница 17: ...he drive carriers to keep you constantly informed of the overall status of the system SC217HQ models include four front panels on the handles of the chassis which control each of the systems This chap...

Страница 18: ...acks and server banks 3 3 Control Panel LEDs The four control panels are located on the front handle of the SC217HQ chassis Each control panel has two additional LEDs These LEDs provide you with criti...

Страница 19: ...SUPERSERVER 2028TP HTR HC0R HC1R SIOM USER S MANUAL 3 4 Notes...

Страница 20: ...nt for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis...

Страница 21: ...en el apartado de traducciones que acompa a a este dispositivo GUARDE ESTAS INSTRUCCIONES IMPORTANTES INFORMATIONS DE S CURIT Ce symbole d avertissement indique un danger Vous vous trouvez dans une si...

Страница 22: ...tection Ensure that the protective device is rated not greater than 250 V 20 A 250 V 20 A 250V 20A 250V 20A Warnung Dieses Produkt ist darauf angewiesen dass im Geb ude ein Kurzschluss bzw berstromsch...

Страница 23: ...Versorgungsteilmodulen entfernt wird bevor es auf den Chassisinnenraum zur ckgreift um Systemsbestandteile anzubringen oder zu entfernen Advertencia El sistema debe ser disconnected de todas las fuent...

Страница 24: ...only through the use of a special tool lock and key or other means of security This warning does not apply to workstations Warnung Diese Einheit ist zur Installation in Bereichen mit beschr nktem Zut...

Страница 25: ...de type semblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de ma...

Страница 26: ...power supply connection All connections must be removed to de energize the unit Warnung Dieses Ger t kann mehr als eine Stromzufuhr haben Um sicherzustellen dass der Einheit kein trom zugef hrt wird...

Страница 27: ...Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is geboden tijdens het onderhoud Advertencia La instalacion de...

Страница 28: ...and other objects away from the openings in the fan assembly s housing Warnung Die L fter drehen sich u U noch wenn die L fterbaugruppe aus dem Chassis genommen wird Halten Sie Finger Schraubendreher...

Страница 29: ...Advertencia Al instalar el producto utilice los cables de conexi n previstos o designados los cables y adaptadores de CA La utilizaci n de otros cables y adaptadores podr a ocasionar un mal funcionam...

Страница 30: ...ezen kabels stroomkabels en adapters Het gebruik van andere kabels en adapters kan leiden tot een storing of een brand Elektrisch apparaat en veiligheidsinformatiebladen wet verbiedt het gebruik van U...

Страница 31: ...center of the board to support it when handling The following measures are generally sufficient to protect your equipment from electric static discharge Precautions Use a grounded wrist strap designed...

Страница 32: ...bles used to transfer data from the peripheral devices have been carefully routed in preconfigured systems to prevent them from blocking the flow of cooling air that moves through the system from fron...

Страница 33: ...lever labeled Open 1st OPEN1st OPEN1st Release the lever labeled Close 1st 2 Press the second load lever labeled Close 1st to release the load plate from its locked position 3 With the second lever f...

Страница 34: ...Close 1st lever fully retracted gently close the load plate Gently close the load plate Installing a Passive CPU Heatsink 1 Do not apply any thermal grease to the heatsink or the CPU die the required...

Страница 35: ...ing attention to the notch along the bottom of the module to prevent inserting the module incorrectly see Figure 5 2 2 Install starting with slot P1 DIMMA1 3 Gently press down on the memory module unt...

Страница 36: ...Width DIMM Capacity GB Speed MT s Voltage V Slot Per Channel SPC DIMM Per Channel DPC 1 Slot Per Channel 2 Slots Per Channel 1DPC 1DPC 2DPC 4Gb 8Gb 1 2V 1 2V 1 2V RDIMM SRx4 8GB 16GB 2133 2133 1866 RD...

Страница 37: ...er Description Default Setting JBT1 Clear CMOS See Section 5 9 JPB1 BMC Enable Disable Pins 1 2 Enabled JPG1 VGA Enable Disable Pins 1 2 Enabled JPME2 Manufacturer s ME Mode Select Pins 1 2 Normal JVR...

Страница 38: ...rear LED Indicator is located at UID_LED1 on the serverboard The front UID switch and the front UID LED are located on the front side of the chassis When the front UID switch or the rear UID switch i...

Страница 39: ...le Disable Watch Dog JWD1 is a system monitor that can reboot the system when a software application hangs Close pins 1 2 to reset the system if an application hangs Close pins 2 3 to generate non mas...

Страница 40: ...ee the table at right for more information Rear UID LED The rear UID LED is located on the rear of the serverboard This LED is used in conjunction with the rear UID switch to provide easy identificati...

Страница 41: ...utilities After creating a CD DVD with the ISO files insert the disk into the CD DVD drive on your system and the display shown in Figure 5 6 should appear S SATA 0 2 CPU2_PCI Express 3 0 x16 Slot SXB...

Страница 42: ...chassis intrusion for multiple systems with SuperDoctor 5 or IPMI SD5 Management Server monitors HTTP FTP and SMTP services to optimize the efficiency of your operation Note The default User Name and...

Страница 43: ...5 24 SUPERSERVER 2028TP HTR HC0R HC1R SIOM USER S MANUAL Notes...

Страница 44: ...very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions Use a grounded wrist strap designed to prevent static discharge Touch a grounded m...

Страница 45: ...to the chassis as shown above 3 Lift the top cover up and off the chassis 4 Peel off the protective film covering the top cover and the top of the chassis 5 Check that all ventilation openings on the...

Страница 46: ...ts obstruct airflow through the chassis Pull all excess cabling out of the airflow path or use shorter cables 4 The control panel LEDs inform you of system status See Chapter 3 System Interface for de...

Страница 47: ...ing up and out of the chassis 4 Push the fan up from the bottom and out of the top of the housing 5 Place the replacement fan into the vacant space in the housing while making sure the arrows on the t...

Страница 48: ...the chassis cover 3 Disconnect the cabling to the backplane 4 Remove all of the hard drive carriers from the front of the chassis 5 Remove the five upper screws at the top of the backplane and the scr...

Страница 49: ...fs in locations used by the serverboards These standoffs accept the rounded Phillips head screws included in the SC217HQ accessories packaging Some serverboards require additional screws for heatsinks...

Страница 50: ...supply as needed Also fans may be temporarily removed to allow access to the backplane ports 10 Replace the expansion card bracket and secure the bracket with a screw 11 Repeat steps 3 5 for the rema...

Страница 51: ...3 Secure the adapter card to the serverboard drawer using the five M3 flathead screws which were previously set aside 4 Reconnect the wiring from the serverboard to the adapter card if necessary 5 Re...

Страница 52: ...es You do not need to access the inside of the chassis or remove power to replace or swap SAS SATA drives Proceed to the next step for instructions You must use standard 1 high SATA drives in the syst...

Страница 53: ...om the chassis These carriers also help promote proper airflow for the drive bays 1 Remove the screws 4 holding connecting the drive tray the carrier 2 Remove the tray from the carrier 3 Install a new...

Страница 54: ...Power Supply Replacement The SC217HQ chassis utilizes two redundant power supplies In the unlikely event that the power supply unit needs to be replaced one power supply can be removed without powerin...

Страница 55: ...hat can be configured Grayed out options cannot be configured Options in blue can be configured by the user The right frame displays the key legend Above the key legend is an area reserved for a text...

Страница 56: ...eed of the memory modules installed in the system How to Start the Setup Utility Normally the only visible Power On Self Test POST routine is the memory test As the memory is being tested press the De...

Страница 57: ...re Inter rupt 19 at bootup immediately and allow the drives that are attached to these host adaptors to function as bootable disks If this item is set to Postponed the ROM BIOS of the host adaptors wi...

Страница 58: ...Enable and Disable DCA Prefetch Delay A DCA Prefetcher is used with a TOE TCP IP Offload Engine adapter to prefetch data in order to shorten execution cycles and maximize data processing efficiency P...

Страница 59: ...evel 2 CPU P State Control Available when Power Technology is set to Custom EIST P states EIST Enhanced Intel SpeedStep Technology allows the system to automatically adjust processor voltage and core...

Страница 60: ...ation 3 8 GT s IOU0 II0 PCIe Port 2 This item configures the PCI E port Bifuraction setting for a PCI E port specified by the user The options are x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 and Auto PORT 2A Link...

Страница 61: ...e Use this item to select the data transfer speed for QPI Link connections The options are Fast and Slow Link Frequency Select Use this item to select the desired frequency for QPI Link connections Th...

Страница 62: ...ns two identical copies of all data in memory for data backup When Lockstep is selected the motherboard uses two areas of memory to run the same set of operations in parallel to boost performance The...

Страница 63: ...Enabled Port 60 64 Emulation Select Enabled to support I O port 60h 64h emulation which will provide complete legacy USB keyboard support for the operating systems that do not support legacy USB devi...

Страница 64: ...without shutting down the system The options are Enabled and Disabled Port 0 Port 5 Spin Up Device On an edge detect from 0 to 1 set this item to allow the PCH to initialize the device The options are...

Страница 65: ...to normal when the I O becomes active The options are Enabled and Disabled sSATA Port 0 Port 3 This item displays the information detected on the installed on the sSATA port specified by the user Mod...

Страница 66: ...figuration settings General ME Configuration Operational Firmware Version Recovery Firmware Version ME Firmware Features ME Firmware Status 1 ME Firmware Status 2 Current State Error Code PCIe PCI PnP...

Страница 67: ...stem boot The default setting for LAN1 Option ROM is PXE for LAN2 Option ROM is Disabled and for Onboard Video Option ROM is Legacy VGA Priority Use this item to select the graphics device to be used...

Страница 68: ...a serial data packet Select 1 Stop Bit for standard serial data communication Select 2 Stop Bits if slower devices are used The options are 1 and 2 Flow Control Use this item to set the flow control f...

Страница 69: ...its if slower devices are used The options are 1 and 2 Flow Control Use this feature to set the flow control for Console Redirection to prevent data loss caused by buffer overflow Send a Stop signal t...

Страница 70: ...vice Support If this feature and the TPM jumper on the motherboard are both set to Enabled onboard security devices will be enabled for TPM Trusted Platform Module sup port to enhance data integrity a...

Страница 71: ...default setting is 10 Erasing Settings Erase Event Log Select Yes to erase all error events in the SMBIOS System Management BIOS log before an event logging is initialized at bootup The options are N...

Страница 72: ...the changes to take effect BMC Network Configuration The following items will be displayed IPMI LAN Selection IPMI Network Link Status Update IPMI LAN Configuration Select Yes for the system BIOS to...

Страница 73: ...Use this feature to set the user password which is required to enter the BIOS setup utility The length of the password should be from 3 characters to 20 char acters long 7 7 Boot Settings Use this fe...

Страница 74: ...o configure the settings below Discard Changes and Exit Select this option to quit the BIOS setup without making any permanent changes to the system configuration and reboot the computer Select Discar...

Страница 75: ...ts Select this item and press Enter to save the current BIOS settings as user s default settings for future use Restore User Defaults Select this item and press Enter to retrieve user defined settings...

Страница 76: ...th your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list on the following page correspond to t...

Страница 77: ...A 2 SUPERSERVER 2028TP HTR HC0R HC1R SIOM USER S MANUAL Notes...

Страница 78: ...MM slots supporting up to 2 TB of LRDIMM Load Reduced DIMM or 1 TB of RDIMM Registered DIMM DDR4 2400 2133 1866 MHz registered ECC memory Note refer to Section 5 6 for details on installation Note che...

Страница 79: ...emperature 0 to 35 C 32 to 95 F Non operating Temperature 40 to 70 C 40 to 158 F Operating Relative Humidity 20 to 95 non condensing Non operating Relative Humidity 5 to 95 non condensing Regulatory C...

Страница 80: ...re to perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell...

Отзывы: