SBI-7125W-S6 Blade Module User’s Manual
6-12
6-6
Security
Choose
Security
from the Phoenix BIOS Setup Utility main menu with the arrow keys.
Security setting options are displayed by highlighting the setting using the arrow keys
and pressing <E
NTER
>. All Security BIOS settings are described in
Table 6-12
below.
Table 6-11. Hardware Monitor Submenu Menu Options
Menu Option
Description
CPU Temperature
Threshold
This option allows the user to set a CPU temperature threshold that will activate
the alarm system when the CPU temperature reaches this pre-set temperature
threshold. The options are 70
o
C,
75
o
C
, 80
o
C and 85
o
C.
The hardware monitor provides the following temperature data:
• PECI Agent 1 Temperature
• PECI Agent 2 Temperature
• System Temperature
Voltage Monitoring
The following voltages are displayed:
• VcoreA
• VcoreB
• +1.8V
• P1V5
• +3.3V
• +12V
• 5Vsb
• 5VDD
• P_VTT
• Vbat
Table 6-12. Security Menu Options
Menu Option
Description
Supervisor Password
Is:
This displays whether a supervisor password has been entered for the system.
Clear means such a password has not been used and Set means a supervisor
password has been entered for the system.
User Password Is:
This displays whether a user password has been entered for the system. Clear
means such a password has not been used and Set means a user password has
been entered for the system.
Set Supervisor
Password
When the item "Set Supervisor Password" is highlighted, hit the <Enter> key.
When prompted, type the Supervisor's password in the dialogue box to set or to
change supervisor's password, which allows access to the BIOS.
Set User Password
When the item "Set User Password" is highlighted, hit the <Enter> key. When
prompted, type the user's password in the dialogue box to set or to change the
user's password, which allows access to the system at boot-up.
Password on Boot
This setting allows you to require a password to be entered when the system
boots up. The options are Enabled (password required) and Disabled (password
not required).
Содержание SuperBlade SBI-7125W-S6
Страница 1: ...SBI 7125W S6 Blade Module User s Manual Revison 1 0...
Страница 4: ...SBI 7125W S6 Blade Module User s Manual iv Notes...
Страница 8: ...SBI 7125W S6 Blade Module User s Manual viii Notes...
Страница 10: ...SBI 7125W S6 Blade Module User s Manual x Notes...
Страница 12: ...SBI 7125W S6 Blade Module User s Manual xii Notes...
Страница 30: ...SBI 7125W S6 Blade Module User s Manual 3 12 Notes...
Страница 38: ...SBI 7125W S6 Blade Module User s Manual 4 8 Notes...
Страница 41: ...5 3 Chapter 5 RAID Setup Procedure Figure 5 1 Customer Information Screen...
Страница 78: ...SBI 7125W S6 Blade Module User s Manual 6 14 Notes...
Страница 88: ...SBI 7125W S6 Blade Module User s Manual A 10 Notes...
Страница 94: ...SBI 7125W S6 Blade Module User s Manual...