![SUPERLOLUX XMS-TYPH-R4-XX Скачать руководство пользователя страница 184](http://html1.mh-extra.com/html/superlolux/xms-typh-r4-xx/xms-typh-r4-xx_user-manual_1403311184.webp)
NVR Software - Appendix
182
Example for a TCP alarm port in SeeTec Network I/O:
Abbildung 19:
Configuring a TCP alarm port
8.2.2
Creating and configuring alarm scenarios
Configure the alarm scenario according to the following points:
Trigger the alarm through a camera’s TCP signal.
A message window will be displayed in case of alarm.
The alarm scenario will always be valid.
Recording duration: 30 seconds, pre-alarm duration: 10 seconds
In the event of an alarm, start recording on the
"M22"
camera.
Only the administrator is entitled to
see
the alarm.
In case of alarm, display the alarm camera in a popup window and mark it as
an alarm camera (= red frame around the camera image).
1. Create a new alarm scenario (in
Configuration Mode
by using the
Alarm
scenarios
option) and select
General
.
Abbildung 20:
Create the alarm scenario
2. Set the priority to 10. This way, a message window will display in case of an
alarm.
3. If you want the alarm to be valid all the time, select
Always
in the
Validity
dropdown list.