background image

WRT4820WS 

Item #

Description

Cat./Part No.

1

Baffle refractory (2 pieces)

PR-ISO2205

2

Back refractory

PR-SR2996

3

Right side refractory

PR-SR2997D

4

Left side refractory

PR-SR2997G

5

Bottom refractory

PR-SR3018

6

Front refractory, right side - ash lip

PR-SR2202D

7

Front refractory, left side - ash lip

PR-SR2202G

8

Secondary air tube

PR-SR2271

9

Bracket, secondary air tube lock

PR-SR2214

10

11

12

13

14

Facing:

          Top trim

          Bottom trim

          Top frame

          Left side frame

          Right side frame

PR-SR3033

PR-SR3020

PR-SR2995

PR-SR2994G

PR-SR2994D

15

Fireplace top

PR-SR2500

16

Fireplace left side

PR-SR2502

17

Fireplace left side

PR-SR2503

18

Fireplace back

PR-SR2499

19

Touch-up paint, aerosol, black metallic

SBMB6309

20

Louvers, upper and lower (set of 2)

LOUVRECF

21

Complete door

PR-SR3003

22

Wooden door handle

PR-SR3027

23

Door handle rod and lock

PR-SR2855

24

Ceramic glass panel

PR-SR3004

25

Gasket, door, 77-3/4” (3/4” dia.)

PR-SR1823O

26

Gasket, glass, 74” (3/16” x 1”)

PR-SR1685J

27

Hinge assembly, fireplace and door 

PR-SR1933

28

Blower 

(heat activated on/off,  pre-wired)

, V2

F3270

29

Snap Disc, Blower

VTU

30

Andiron (2)

PR-SR3026

---

Blower 250 CFM for central forced air 

kit, BISZY

BISZY

---

Blower variable speed control with decora-

tive wall plate for (BISZY), VRUW

VRUW

---

Thermo-disk, on/off blower control (for 

BISZY), VTU

VTU

---

Blower to flexible pipe adaptor, BISAVF

BISAVF

---

Backdraft damper, BISBD

BISBD

---

Fireplace to Flex adaptor and 2 clamps, 

BISAF

BISAF

REPLACEMENT PARTS - WRT4820WS

Contact an IHP dealer to obtain any of these parts. Never use substitute 

materials not approved by IHP. Use of non-approved parts can result 

in poor performance and safety hazards.

CLEARANCE TO COMBUSTIBLES

The following clearances meet the minimum requirements for a safe 

installation:

Side wall: 

24” (610 mm) measured from the fireplace side.

Ceiling:

  6’ 8”  (2,032 mm) measured from the base of the fireplace.

Fireplace enclosure:

 

Bottom

:  0”

Side:

   0” to spacer

Back:

   0” to spacer

Top:

 Do not fill the space above the fireplace with any material 

(Except the wood framing.  See 

Page 11, Figure 11).

Chimney:

  2” (50 mm)

Mantel: 

45”  (1143 mm) measured from the base of the fireplace.

SPECIFICATIONS

Cat. No.

Model

F1794

WRT4820WS

Product Reference Information

Weight

385 lbs 

Height

36”

Width

36”

Depth

24-1/2”

Firebox W x H x D - measured in front

22” x 11-3/4” x 12”

Chimney weight ASHT (6” dia)

6.25 lb per linear foot

Chimney weight AC (6” dia)

3.25 lb per linear foot

Model

Emission Rate

Heat Output

EPA Estimated 

Efficiency

WRT4820WS

3.7 g/hr

10,442-27,746 btu/hr

63%

25

Содержание WRT4820

Страница 1: ...re burns may result Carefully supervise children in the same room as appliance If small children are present in the home it is recommended that this appliance be fitted with an adjustable safety gate...

Страница 2: ...ructions and using only IHP components This fireplace has been tested for CAN ULC S610 M87 and ANSI UL 127 under report number 3011202 It has also been tested for EPA 40 C F R Part 60 section 60 532 b...

Страница 3: ...e it is burning WARNING Always ensure that the air inlet to the fireplace is free from debris and any other obstructions that can block the entrance of air WARNING Neither the manufacturer nor the sel...

Страница 4: ...d is relative to its density Hardwoods will result in a longer burning fire and less frequent refueling A moisture content of 15 to 20 seasoned is recommended Wood that has been cut and split and let...

Страница 5: ...Poor chimney draft With no fire there shouldbesufficientdrafttoexhaustcigarette smoke introduced under the baffle Chim neysinstalledagainstanoutsidewallwithout protectionmaygeneratebackdraftproblems w...

Страница 6: ...Inspector What does Well Seasoned mean When a tree is cut down the wood is green full of sap and moisture This moisture content can exceed 80 which must be reduced to less than 20 Wood properly seaso...

Страница 7: ...t ceramic baffle 7 Remove the rear ceramic baffle To install the new refractories follow the above steps in reverse DOOR INSTALLATION Your fireplaces door has been factory installed and adjusted To re...

Страница 8: ...t is needed The WRT4820WS fireplace may be installed directly on the floor or on a raised base for proper guidelines refer to Hearth Extension Requirements and a minimum of 6 8 2 m measured from the b...

Страница 9: ...he clean face kit to allow hot air flow that wouldnormallycomeoutofthetoplouver ANY OTHER INSTALLATION MAY RESULT IN THE FIREPLACE OVERHEATING AND POTENTIALLY CAUSE A FIRE See Gravity Kit section on P...

Страница 10: ...eplace must be covered with a non combustible material tile marble stone etc See Figures 9 and 10 COLD CLIMATE INSTALLATIONS Climates where temperatures will fall below 32 F 0 C The heating performanc...

Страница 11: ...n instructions Product designs materials dimensions specifications colorsandpricesare subjecttochangeordiscontinuance without notice All framing dimensions calculated for1 2 drywallatthefireplaceface...

Страница 12: ...4 m Level Outside Base Insulation Thermal Barrier Solid Continuous Surface NOTE It is recommended that the chase walls and floor be insulated in the same manner using the same insulation as the rest...

Страница 13: ...an not overlay on the fireplace front black steel faceofthefireplace seeFigures16and17 Non combustible materials such as brick stone or ceramic tile can project in front of and onto the fireplace faci...

Страница 14: ...lengths H8951 When installing the double outlet system the hotairoutletscanbeinstalledinthesameroom as the fireplace or one or both of the outlets can be installed in adjacent or upper rooms Installin...

Страница 15: ...henusing the double hot air outlet kit and blocking the upper louver of the fireplace CENTRAL FORCED AIR KIT NOT TESTED UNDER EPA CERTIFICATION The knock outs provided on the back and on the sides of...

Страница 16: ...must not draw air from the attic from the basement or garage D The air intake should be installed where it is not likely to be blocked by snow or exposed to extreme wind and away from automobile exha...

Страница 17: ...in an insulated chase 3 The fireplace model WRT4820WS may be installed only with Security Chimneys Ltd 6 diameter chimney systems or DuraVent models DuraTech and DuraTech DTC chimney systems 4 A chim...

Страница 18: ...AC chimney youmustuseastarter section AC6SB or AC6SB30 before installing the first chimney length Figure 30 Continue installing chimney lengths making sure to lock each length in place 4 Every time th...

Страница 19: ...2 12 mm screws If the offset lengthismadeoftwo 2 chimneylengthsor more use an offset or roof support halfway up the offset If penetrating a wall install a wall radiation shield see Figures 34 and 36...

Страница 20: ...6 122 mm 6 1 8 156 mm 11 280 mm 14 1 8 359 mm 16 7 8 429 mm 18 7 16 468 mm 23 584 mm 26 3 16 665 mm B 27 11 16 703 mm 33 1 2 851 mm 50 7 8 1292 mm 62 1 2 1588 mm 72 5 8 1845 mm 78 7 16 1992 mm 95 3 4...

Страница 21: ...ney at a 30 or 45 angle an angled firestop or wall radiation shield must be installed Only one is required NOTE 45 angle for Canada only RSMI45 6DTC S45 In cold climate locations climates where temper...

Страница 22: ...weight will lie on the support not on the fireplace to reduce expansion noises This support has three possible uses 1 For ASHT HT6103 and S 2100 HT6000 DuraTech DTC it must be used on a roof to suppo...

Страница 23: ...Cement Firestop Tubinox or Projet SS Stainless Steel Liner Insulated Length Masonry Chimney New or Existing Tubinox or Projet SS Liner Must Slide at Least 2 Inside Length 6 8 Available from Security C...

Страница 24: ...5 7B26ZL2A H8951 Length two 2 feet 8KL2 H8954 Length one 1 feet 8KL1 H8953 Wall radiation shield 8 I D 7B26ZR H8952 OPTIONAL INSTALLATION ACCESSORIES uNot tested under EPA certification If installed...

Страница 25: ...ed air kit BISZY BISZY Blower variable speed control with decora tive wall plate for BISZY VRUW VRUW Thermo disk on off blower control for BISZY VTU VTU Blower to flexible pipe adaptor BISAVF BISAVF B...

Страница 26: ...REPLACEMENT PARTS WRT4820WS 1 8 15 16 17 20 10 14 12 11 13 20 22 23 24 21 25 26 30 19 2 3 4 5 6 7 PA I N T 18 28 29 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 26...

Страница 27: ...rts Offset Support SO Roof Support ST Roof Brace BS2 Firestops Firestop 6BF Radiation Shield 6RS Insulated Attic Radiation Shield 6RSA2 Insulated Wall Radiation Shield 6RSM Insulated Wall Radiation Sh...

Страница 28: ...eld 8 I D 7B26ZR 7B26ZR Black grill with support 7B30ZO 7B30ZO Brass grill for 7B30ZK 7B30ZGB 7B30ZGB Length one 1 feet 8KL1 8KL1 Length two 2 feet 8KL2 8KL2 Length three 3 feet 8KL3 8KL3 Length four...

Страница 29: ...NERIE TEL QUE D CRIT DANS LE MANUEL D INSTALLATION LES COMPOSANTES UTILIS ES AVEC LE FOYER DOIVENT TRE HO MOLOGU ES VOIR LA LISTE DANS LE MANUEL D INSTALLATION REMPLACER LA VITRE AVEC UN VERRE C RAMIQ...

Страница 30: ...NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 30...

Страница 31: ...l use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with abnormal burning cha...

Страница 32: ...See Page 25 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at p...

Отзывы: