Figure 36
Drywall
Insulated Wall
Insulated Wall
Radiation Shield
*
Figure 34 - Offset Chimney Installation
*
Figure 35
Insulated Wall
Radiation Shield
Support
Straps
ACRS
Chimney AC
Starter Section
Straps
Rain Cap
Collar
Roof Flashing
Offset Support
Framing
2” x 3”
NOTE: This illustration is not to scale. It represents how the chimney
must be supported. A 30 degree offset only is allowed in the USA
and a 45 degree maximum offset is allowed in Canada.
NOTE: In cold areas it is recommended to
protect the chimney in a insulated chase.
*
Available from Security Chimneys
®
ANGLED WALL RADIATION SHIELD
*
When traversing a combustible wall with the chimney at a 30º or 45º
angle, an angled firestop or wall radiation shield must be installed. Only
one is required.
NOTE: 45º angle for Canada only (
RSMI45
*
/ 6DTC-S45)
In cold climate locations (climates where temperatures will fall below 32°
F / 0° C), we recommend that you use the insulated wall radiation shield
since it will maintain the home’s thermal barrier.
Security Chimneys
®
RSM+ and RSMI30
(RSMI45 - Canada Only)
DuraVent
®
6DTC-WTI and 6DTC-S30
(6DTC-S45 - Canada Only)
Chimney Model
Angle
Hole Size
ASHT / (6” dia).
Canada only
30º
283 mm x 781 mm (11-1/8” x 30-3/4”)
45º
283 mm x 518 mm (11-1/8” x 20-3/8”)
DuraTech DTC
**
(6” dia). Canada only
30º
283 mm x 781 mm (11-1/8” x 30-3/4”)
45º
283 mm x 518 mm (11-1/8” x 20-3/8”)
S-2100+ / / AC
(6” dia).
30º
327 mm x 881 mm (12-7/8” x 34-11/16”)
30º
380 mm x 972 mm (15” x 38-1/4”)
Table 5
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
21