background image

       WARNING 

To avoid the risk of damaging 

fireplace materials and increas-

ing the risk of fire, do not use the 

fireplace to cook or warm food.

IMPORTANT! GENERAL SAFETY 

PRECAUTIONS. READ AND 

UNDERSTAND THESE SAFETY 

RULES BEFORE YOUR FIRST FIRE.

       IMPORTANT 

When burning wood, use SOLID 

NATURAL  DRY WELL-SEASONED 

WOOD ONLY.  Hardwoods are rec-

ommended (soft woods tend to burn 

very quickly).  

• DO NOT burn treated wood, 

charcoal, coal, trash, cardboard, 

driftwood, woods dipped in tar, 

Christmas tree greens, pitch, pine 

tar, creosote, chemical chimney 

cleaners, flame colorants, poly-

styrene packaging, wood prod-

ucts with synthetic binders (i.e. 

plywood).  Plywood, lumber and 

other misc. materials can produce 

abnormally high temperatures, 

sputtering and smoking fires and 

may contain hazardous chemicals 

to treat insects and fungus.

•  Burning unapproved fuels can 

produce excessive temperatures, 

beyond the design capabilities 

of the fireplace and may produce 

excess sparks or may contain 

hazardous chemicals.  Burning 

unapproved fuels can result in 

a chimney fire, a house fire, 

personal injury, death or loss of 

property.

 

       WARNING 

Never leave children unattended 

when there is a fire burning in the 

fireplace.

       WARNING 

NEVER use gasoline, gasoline-

type lantern fuel, kerosene, 

charcoal lighter fluid, naphtha, 

engine oil or similar liquids to 

start or “freshen up” a fire in this 

fireplace. Keep any flammable 

liquids a safe distance from the 

fireplace at all times. 

       WARNING 

Use care when selecting window 

treatments for windows located 

near the fireplace.  Avoid using 

combustible flowing window 

treatments such as curtains on 

nearby windows that are of suf-

ficient length to be blown in front 

of an open flame when the window 

is opened.  Keep any combustible 

furniture, materials or decorative 

pillows at least 48" (1219 mm) 

from the front fireplace opening.

       WARNING 

Never modify or alter your fireplace 

system in any way. To do so may 

create a potential fire hazard and 

void the limited warranty

, listings 

and approvals of this system.

       WARNING 

Never leave your fireplace unat-

tended while it is burning.

       WARNING 

Always ensure that the air inlet to 

the fireplace is free from debris 

and any other obstructions that 

can block the entrance of air.

       WARNING 

Neither the manufacturer nor the 

seller warrants “smoke free” 

operation nor are we respon-

sible for inadequate system draft 

caused by mechanical systems, 

general construction conditions, 

inadequate chimney heights, 

adverse wind conditions and/or 

unusual environmental factors 

or conditions beyond our control. 

       IMPORTANT 

WHEN INSTALLED IN A MOBILE OR 

MANUFACTURED HOME:

• Mobile or manufactured home 

installations must be installed in 

accordance with the requirements 

of the Department of Housing and 

Urban Development (HUD) “Mobile 

Home Construction and Safety stan-

dards” for US or Canada Mortgage 

and Housing Corporation (CMHC) 

for Canada.

• The fireplace must be fastened to 

the floor by unfolding and screwing 

the small tabs on both sides at the 

bottom of the fireplace.   

• It is necessary to have access 

openings, for inspection purpose 

only, into built-in enclosures sur-

rounding the fireplace installation.  

Such openings to require a house-

hold tool for access.

• The vapor barrier of the mobile 

home shall be as close as possible 

of the location where the chimney 

assembly penetrates the ceiling 

and roof structure with no interfer-

ence to the required clearance to 

combustible material. 

• When the mobile or manufactured 

home has a flat roof, the Attic Radia-

tion Shield  must be installed from 

below going through the roof (See 

Figures 29b and 29d)

.

•  Warning: Do not install in a 

sleeping room.

•  Caution: The structural integrity 

of the manufactured home floor, 

wall, and ceiling/roof must be 

maintained.

    WARNING

THIS FIREPLACE HAS NOT BEEN 

TESTED WITH AN UNVENTED 

GAS LOGS OR A FIREPLACE 

INSERT. TO REDUCE RISK 

OF FIRE OR INJURY, DO NOT 

INSTALL AN UNVENTED GAS 

LOG SET OR FIREPLACE INSERT 

OR OTHER PRODUCTS NOT 

SPECIFIED FOR USE WITH THIS 

FIREPLACE.

  WARNING

THE FIREPLACE MUST BE OPER-

ATED WITH THE DOOR FULLY 

OPENED OR DOOR FULLY CLOSED. 

IF THE DOORS ARE LEFT PARTLY 

OPENED, GAS AND FLAME MAY BE 

DRAWN OUT OF THE FIREPLACE 

OPENING, CREATING RISKS OF 

BOTH FIRE AND SMOKE. IF THE 

UNIT IS OPERATED WITH THE 

DOORS FULLY OPENED, THE 

OPTIONAL FIRESCREEN MUST 

BE USED.

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

3

Содержание WRT4820

Страница 1: ...re burns may result Carefully supervise children in the same room as appliance If small children are present in the home it is recommended that this appliance be fitted with an adjustable safety gate...

Страница 2: ...ructions and using only IHP components This fireplace has been tested for CAN ULC S610 M87 and ANSI UL 127 under report number 3011202 It has also been tested for EPA 40 C F R Part 60 section 60 532 b...

Страница 3: ...e it is burning WARNING Always ensure that the air inlet to the fireplace is free from debris and any other obstructions that can block the entrance of air WARNING Neither the manufacturer nor the sel...

Страница 4: ...d is relative to its density Hardwoods will result in a longer burning fire and less frequent refueling A moisture content of 15 to 20 seasoned is recommended Wood that has been cut and split and let...

Страница 5: ...Poor chimney draft With no fire there shouldbesufficientdrafttoexhaustcigarette smoke introduced under the baffle Chim neysinstalledagainstanoutsidewallwithout protectionmaygeneratebackdraftproblems w...

Страница 6: ...Inspector What does Well Seasoned mean When a tree is cut down the wood is green full of sap and moisture This moisture content can exceed 80 which must be reduced to less than 20 Wood properly seaso...

Страница 7: ...t ceramic baffle 7 Remove the rear ceramic baffle To install the new refractories follow the above steps in reverse DOOR INSTALLATION Your fireplaces door has been factory installed and adjusted To re...

Страница 8: ...t is needed The WRT4820WS fireplace may be installed directly on the floor or on a raised base for proper guidelines refer to Hearth Extension Requirements and a minimum of 6 8 2 m measured from the b...

Страница 9: ...he clean face kit to allow hot air flow that wouldnormallycomeoutofthetoplouver ANY OTHER INSTALLATION MAY RESULT IN THE FIREPLACE OVERHEATING AND POTENTIALLY CAUSE A FIRE See Gravity Kit section on P...

Страница 10: ...eplace must be covered with a non combustible material tile marble stone etc See Figures 9 and 10 COLD CLIMATE INSTALLATIONS Climates where temperatures will fall below 32 F 0 C The heating performanc...

Страница 11: ...n instructions Product designs materials dimensions specifications colorsandpricesare subjecttochangeordiscontinuance without notice All framing dimensions calculated for1 2 drywallatthefireplaceface...

Страница 12: ...4 m Level Outside Base Insulation Thermal Barrier Solid Continuous Surface NOTE It is recommended that the chase walls and floor be insulated in the same manner using the same insulation as the rest...

Страница 13: ...an not overlay on the fireplace front black steel faceofthefireplace seeFigures16and17 Non combustible materials such as brick stone or ceramic tile can project in front of and onto the fireplace faci...

Страница 14: ...lengths H8951 When installing the double outlet system the hotairoutletscanbeinstalledinthesameroom as the fireplace or one or both of the outlets can be installed in adjacent or upper rooms Installin...

Страница 15: ...henusing the double hot air outlet kit and blocking the upper louver of the fireplace CENTRAL FORCED AIR KIT NOT TESTED UNDER EPA CERTIFICATION The knock outs provided on the back and on the sides of...

Страница 16: ...must not draw air from the attic from the basement or garage D The air intake should be installed where it is not likely to be blocked by snow or exposed to extreme wind and away from automobile exha...

Страница 17: ...in an insulated chase 3 The fireplace model WRT4820WS may be installed only with Security Chimneys Ltd 6 diameter chimney systems or DuraVent models DuraTech and DuraTech DTC chimney systems 4 A chim...

Страница 18: ...AC chimney youmustuseastarter section AC6SB or AC6SB30 before installing the first chimney length Figure 30 Continue installing chimney lengths making sure to lock each length in place 4 Every time th...

Страница 19: ...2 12 mm screws If the offset lengthismadeoftwo 2 chimneylengthsor more use an offset or roof support halfway up the offset If penetrating a wall install a wall radiation shield see Figures 34 and 36...

Страница 20: ...6 122 mm 6 1 8 156 mm 11 280 mm 14 1 8 359 mm 16 7 8 429 mm 18 7 16 468 mm 23 584 mm 26 3 16 665 mm B 27 11 16 703 mm 33 1 2 851 mm 50 7 8 1292 mm 62 1 2 1588 mm 72 5 8 1845 mm 78 7 16 1992 mm 95 3 4...

Страница 21: ...ney at a 30 or 45 angle an angled firestop or wall radiation shield must be installed Only one is required NOTE 45 angle for Canada only RSMI45 6DTC S45 In cold climate locations climates where temper...

Страница 22: ...weight will lie on the support not on the fireplace to reduce expansion noises This support has three possible uses 1 For ASHT HT6103 and S 2100 HT6000 DuraTech DTC it must be used on a roof to suppo...

Страница 23: ...Cement Firestop Tubinox or Projet SS Stainless Steel Liner Insulated Length Masonry Chimney New or Existing Tubinox or Projet SS Liner Must Slide at Least 2 Inside Length 6 8 Available from Security C...

Страница 24: ...5 7B26ZL2A H8951 Length two 2 feet 8KL2 H8954 Length one 1 feet 8KL1 H8953 Wall radiation shield 8 I D 7B26ZR H8952 OPTIONAL INSTALLATION ACCESSORIES uNot tested under EPA certification If installed...

Страница 25: ...ed air kit BISZY BISZY Blower variable speed control with decora tive wall plate for BISZY VRUW VRUW Thermo disk on off blower control for BISZY VTU VTU Blower to flexible pipe adaptor BISAVF BISAVF B...

Страница 26: ...REPLACEMENT PARTS WRT4820WS 1 8 15 16 17 20 10 14 12 11 13 20 22 23 24 21 25 26 30 19 2 3 4 5 6 7 PA I N T 18 28 29 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 26...

Страница 27: ...rts Offset Support SO Roof Support ST Roof Brace BS2 Firestops Firestop 6BF Radiation Shield 6RS Insulated Attic Radiation Shield 6RSA2 Insulated Wall Radiation Shield 6RSM Insulated Wall Radiation Sh...

Страница 28: ...eld 8 I D 7B26ZR 7B26ZR Black grill with support 7B30ZO 7B30ZO Brass grill for 7B30ZK 7B30ZGB 7B30ZGB Length one 1 feet 8KL1 8KL1 Length two 2 feet 8KL2 8KL2 Length three 3 feet 8KL3 8KL3 Length four...

Страница 29: ...NERIE TEL QUE D CRIT DANS LE MANUEL D INSTALLATION LES COMPOSANTES UTILIS ES AVEC LE FOYER DOIVENT TRE HO MOLOGU ES VOIR LA LISTE DANS LE MANUEL D INSTALLATION REMPLACER LA VITRE AVEC UN VERRE C RAMIQ...

Страница 30: ...NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 30...

Страница 31: ...l use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with abnormal burning cha...

Страница 32: ...See Page 25 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at p...

Отзывы: