Aluminum Tape

Aluminum Tape

Fireplace

Connection

Plastic

Cover

Insulation

Flexible Pipe

Fireplace

OUTSIDE AIR CONNECTION TO THE FIREPLACE

Figure 26

OUTSIDE AIR KIT - REQUIRED (Included w/fireplace)

During operation, the fireplace requires fresh air for combustion and 

draws air out of the house.  It may starve other fuel burning appliances 

such as gas or oil furnaces.  As well, exhaust blowers may compete for 

air, causing negative pressure in the house, resulting in smoke entering 

the house from the fireplace. This situation is aggravated in modern 

airtight houses. To overcome this problem, we strongly recommend that 

you install an outside air assembly. Check with local authorities having 

jurisdiction in your area, it may be mandatory.

NOTE: Should you decide not to install the outside air assembly, 

proceed as follows:

-  Remove the bottom grill. The air box is located on front left and is on 

a slant. 

-  Unscrew the four screws holding the inside air box covering plate and 

remove it.

Outside Air Installation

The outside air assembly may be installed according to the following 

requirements:

A) Duct length should be kept to a minimum.  The maximum length of 

duct is twenty (20) feet (6.1 m) for a 4 in. dia. pipe (See note below).

B) The air intake register must not be installed more than ten (10) feet 

(3050 mm) above the base of the fireplace.

C) The fresh air must come from outside the house.  The air intake must 

not draw air from the attic, from the basement or garage.

D) The air intake should be installed where it is not likely to be blocked by 

snow or exposed to extreme wind and away from automobile exhaust 

fumes, gas meters and other vents.

E) The duct and register may be installed above or below floor level.

The following components are required:

-  Outside air kit (UZI)  (includes 4 inch flex that goes up to ten (10) feet 

long)

-  4” Adaptor for fireplace connection (supplied with the unit)

Make a 4-1/4” (110 mm) hole in the outside wall of the house at the chosen 

location. From outside, place the outside air register in the hole (open 

side down) and fasten the register to the wall, with screws as shown (see 

Figure 25)

.  Slip the pipe into the insulated sleeve.  Place the insulated 

pipe over the register tube and over the fireplace’s outside air connector 

(see

 Figure 26)

. At each end, carefully pull back the insulation and plastic 

cover exposing the flexible pipe.  Using the aluminium tape provided, 

wrap the tape around the joint between the flexible pipe and the air inlets.  

Carefully push the insulation and plastic cover back over the pipe.  Using 

aluminium tape, fasten the plastic cover in place.

NOTE: 

We recommend not to exceed 20 feet of 4” flexible pipe.  If you 

require a longer length we recommend that you use a 5” diameter flex-

ible pipe for the complete run up to 30 feet and a 6” diameter pipe for a 

run of up to 40 feet.

Figure 25

OUTSIDE CONNECTION

Outside

Intake

Screw

Opening

Facing

Down

Wall

Aluminum Tape

Plastic Cover

Insulation

Flexible Pipe

Aluminum Tape

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

16

Содержание WRT4820

Страница 1: ...re burns may result Carefully supervise children in the same room as appliance If small children are present in the home it is recommended that this appliance be fitted with an adjustable safety gate...

Страница 2: ...ructions and using only IHP components This fireplace has been tested for CAN ULC S610 M87 and ANSI UL 127 under report number 3011202 It has also been tested for EPA 40 C F R Part 60 section 60 532 b...

Страница 3: ...e it is burning WARNING Always ensure that the air inlet to the fireplace is free from debris and any other obstructions that can block the entrance of air WARNING Neither the manufacturer nor the sel...

Страница 4: ...d is relative to its density Hardwoods will result in a longer burning fire and less frequent refueling A moisture content of 15 to 20 seasoned is recommended Wood that has been cut and split and let...

Страница 5: ...Poor chimney draft With no fire there shouldbesufficientdrafttoexhaustcigarette smoke introduced under the baffle Chim neysinstalledagainstanoutsidewallwithout protectionmaygeneratebackdraftproblems w...

Страница 6: ...Inspector What does Well Seasoned mean When a tree is cut down the wood is green full of sap and moisture This moisture content can exceed 80 which must be reduced to less than 20 Wood properly seaso...

Страница 7: ...t ceramic baffle 7 Remove the rear ceramic baffle To install the new refractories follow the above steps in reverse DOOR INSTALLATION Your fireplaces door has been factory installed and adjusted To re...

Страница 8: ...t is needed The WRT4820WS fireplace may be installed directly on the floor or on a raised base for proper guidelines refer to Hearth Extension Requirements and a minimum of 6 8 2 m measured from the b...

Страница 9: ...he clean face kit to allow hot air flow that wouldnormallycomeoutofthetoplouver ANY OTHER INSTALLATION MAY RESULT IN THE FIREPLACE OVERHEATING AND POTENTIALLY CAUSE A FIRE See Gravity Kit section on P...

Страница 10: ...eplace must be covered with a non combustible material tile marble stone etc See Figures 9 and 10 COLD CLIMATE INSTALLATIONS Climates where temperatures will fall below 32 F 0 C The heating performanc...

Страница 11: ...n instructions Product designs materials dimensions specifications colorsandpricesare subjecttochangeordiscontinuance without notice All framing dimensions calculated for1 2 drywallatthefireplaceface...

Страница 12: ...4 m Level Outside Base Insulation Thermal Barrier Solid Continuous Surface NOTE It is recommended that the chase walls and floor be insulated in the same manner using the same insulation as the rest...

Страница 13: ...an not overlay on the fireplace front black steel faceofthefireplace seeFigures16and17 Non combustible materials such as brick stone or ceramic tile can project in front of and onto the fireplace faci...

Страница 14: ...lengths H8951 When installing the double outlet system the hotairoutletscanbeinstalledinthesameroom as the fireplace or one or both of the outlets can be installed in adjacent or upper rooms Installin...

Страница 15: ...henusing the double hot air outlet kit and blocking the upper louver of the fireplace CENTRAL FORCED AIR KIT NOT TESTED UNDER EPA CERTIFICATION The knock outs provided on the back and on the sides of...

Страница 16: ...must not draw air from the attic from the basement or garage D The air intake should be installed where it is not likely to be blocked by snow or exposed to extreme wind and away from automobile exha...

Страница 17: ...in an insulated chase 3 The fireplace model WRT4820WS may be installed only with Security Chimneys Ltd 6 diameter chimney systems or DuraVent models DuraTech and DuraTech DTC chimney systems 4 A chim...

Страница 18: ...AC chimney youmustuseastarter section AC6SB or AC6SB30 before installing the first chimney length Figure 30 Continue installing chimney lengths making sure to lock each length in place 4 Every time th...

Страница 19: ...2 12 mm screws If the offset lengthismadeoftwo 2 chimneylengthsor more use an offset or roof support halfway up the offset If penetrating a wall install a wall radiation shield see Figures 34 and 36...

Страница 20: ...6 122 mm 6 1 8 156 mm 11 280 mm 14 1 8 359 mm 16 7 8 429 mm 18 7 16 468 mm 23 584 mm 26 3 16 665 mm B 27 11 16 703 mm 33 1 2 851 mm 50 7 8 1292 mm 62 1 2 1588 mm 72 5 8 1845 mm 78 7 16 1992 mm 95 3 4...

Страница 21: ...ney at a 30 or 45 angle an angled firestop or wall radiation shield must be installed Only one is required NOTE 45 angle for Canada only RSMI45 6DTC S45 In cold climate locations climates where temper...

Страница 22: ...weight will lie on the support not on the fireplace to reduce expansion noises This support has three possible uses 1 For ASHT HT6103 and S 2100 HT6000 DuraTech DTC it must be used on a roof to suppo...

Страница 23: ...Cement Firestop Tubinox or Projet SS Stainless Steel Liner Insulated Length Masonry Chimney New or Existing Tubinox or Projet SS Liner Must Slide at Least 2 Inside Length 6 8 Available from Security C...

Страница 24: ...5 7B26ZL2A H8951 Length two 2 feet 8KL2 H8954 Length one 1 feet 8KL1 H8953 Wall radiation shield 8 I D 7B26ZR H8952 OPTIONAL INSTALLATION ACCESSORIES uNot tested under EPA certification If installed...

Страница 25: ...ed air kit BISZY BISZY Blower variable speed control with decora tive wall plate for BISZY VRUW VRUW Thermo disk on off blower control for BISZY VTU VTU Blower to flexible pipe adaptor BISAVF BISAVF B...

Страница 26: ...REPLACEMENT PARTS WRT4820WS 1 8 15 16 17 20 10 14 12 11 13 20 22 23 24 21 25 26 30 19 2 3 4 5 6 7 PA I N T 18 28 29 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 26...

Страница 27: ...rts Offset Support SO Roof Support ST Roof Brace BS2 Firestops Firestop 6BF Radiation Shield 6RS Insulated Attic Radiation Shield 6RSA2 Insulated Wall Radiation Shield 6RSM Insulated Wall Radiation Sh...

Страница 28: ...eld 8 I D 7B26ZR 7B26ZR Black grill with support 7B30ZO 7B30ZO Brass grill for 7B30ZK 7B30ZGB 7B30ZGB Length one 1 feet 8KL1 8KL1 Length two 2 feet 8KL2 8KL2 Length three 3 feet 8KL3 8KL3 Length four...

Страница 29: ...NERIE TEL QUE D CRIT DANS LE MANUEL D INSTALLATION LES COMPOSANTES UTILIS ES AVEC LE FOYER DOIVENT TRE HO MOLOGU ES VOIR LA LISTE DANS LE MANUEL D INSTALLATION REMPLACER LA VITRE AVEC UN VERRE C RAMIQ...

Страница 30: ...NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 30...

Страница 31: ...l use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with abnormal burning cha...

Страница 32: ...See Page 25 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at p...

Отзывы: