background image

2

IMPORTANT SAFETY 

INFORMATION

INSTALLER: PLEASE LEAVE THESE INSTRUC-
TIONS WITH THE OWNER.
OWNER: PLEASE RETAIN THESE INSTRUC-
TIONS FOR FUTURE REFERENCE.

     

WARNING

If the information in this 

manual is not followed 

exactly, a fire or explosion 

may result causing prop-

erty damage, personal 

injury or loss of life.

       

IMPORTANT

Before starting your firebox instal-

lation, read these installation 

instructions carefully to be sure you 

understand them completely and 

in entirety. Failure to follow these 

instructions could cause a heater 

malfunction resulting in serious 

injury and/or property damage.

       

IMPORTANT

The fireplace screens on the appli-

ance must be closed prior to operat-

ing the fireplace.

       

WARNING

These built-in vent-free fireboxes 

have only been tested and approved 

for use with ANSI Z21.11.2 Vent-

free gas logs.

       

WARNING

Any change to this Vent-Free room 

heater can be dangerous. Improper 

installation or use of this heater can 

cause serious injury or death from 

fire, burns, explosion or carbon 

monoxide poisoning.

       

WARNING

Do not attempt to burn solid wood 

fuels, other gas log sets or any 

other combustible materials in this 

vent-free firebox.

       

WARNING

Carbon Monoxide Poisoning: Early 

signs of carbon monoxide poisoning 

are similar to the flu with head-

aches, dizziness and/or nausea. If 

you have these signs, obtain fresh 

air immediately. Have the Vent-Free 

Gas Heater serviced as it may not 

be operating correctly.

       

WARNINGS

• Due to high temperatures, the 

firebox should be located out of 

traffic and away from furniture 

and draperies.

• Do not place clothing or other 

flammable material on or near 

the heater.

• Any safety screen or guard re-

moved for servicing the firebox 

must be replaced and/or closed 

prior to operating the heater.

• Installation and repair should 

be done by a qualified service 

person. The heater should be 

inspected before use and at 

least annually by a professional 

service person. More frequent 

cleaning may be required due 

to excessive lint from carpet-

ing, bedding material, etc. It is 

important that control compart-

ments, burners and circulating 

air passageways of the heater 

be kept clean.

•  Allow the heater to cool before 

servicing. Always shut off any 

electricity or gas to the heater 

while performing service work.

• Do not install the firebox in a 

sleeping room or bathroom.

•  The appliance and its individual 

shut-off valve must be discon-

nected from the gas supply piping 

system while performing any 

tests of the gas supply piping 

system at test pressures equal 

to or less than 1/2 psig.

       

WARNING

•  The heater must be isolated from 

the gas supply piping system by 

closing its individual manual 

shut-off valve during any pres-

sure testing of the gas supply 

piping system at test pressures 

equal to or less than 1/2 psig.

•  Keep heater area clear and free 

from combustible materials, 

gasoline and other flammable 

vapors and liquids.

• Do not use this heater if any 

part has been under water. Im-

mediately call a qualified service 

technician to inspect the heater 

and to replace any part of the con-

trol system and any gas control 

which has been under water.

•  Ensure that the heater is clean 

when operating. Excessive dust 

accumulation on the burner and 

logs will increase the amount of 

carbon monoxide formation and 

could lead to carbon monoxide 

poisoning and death.

       

WARNING

Do not install in the vicinity where 

gasoline or other flammable liq-

uids may be stored. The Vent-Free 

firebox must be kept clear and free 

from these combustible materials.

       

WARNING

Maintain minimum clearances.

       

WARNING

Do not allow fans to blow directly 

into the fireplace. Avoid any drafts 

that alter burner flame patterns.

Содержание VRT3132F

Страница 1: ...3132F VRT3136WS VRT3136F VRT3142WS VRT3142F WARNING If the information in this manual is not followed exactly a fire or explosion may resultcausingpropertydamage personalinjury or loss of life FOR USE...

Страница 2: ...perating the heater Installation and repair should be done by a qualified service person The heater should be inspected before use and at least annually by a professional service person More frequent...

Страница 3: ...UCTIONS BEFORE BEGIN NING YOUR INSTALLATION Packaging List Vent Free Gas Firebox Hood Installation and Operation Instructions GENERAL INFORMATION TheseVent Freefireboxenclosuresaredesigned toacceptall...

Страница 4: ...maximum BTU Hr the space can support with the actual amount of BTU Hr used __________ BTU Hr max the space can support __________ BTU Hr actual amount of BTU Hr used Example 61 440 BTU Hr max the spac...

Страница 5: ...ree firebox must be kept clear and free from these combustible materials WARNING Do not use a blower insert heat exchanger insert or other acces sory not approved for use with this appliance WARNING D...

Страница 6: ...bstruct vent openings for heat circulating models NOTE To avoid heat related finish damage we recommend the use of high temperature paint rated 175 F or higher on the underside of the mantel Clearance...

Страница 7: ...ch as carpeting vinyl tile etc a metal or wood barrier covering the entire bottom surface must be used Combustible Mantel and Trim Clearance VRT3100 Series Models WITH Hood Installed Hood is required...

Страница 8: ...ifferent sequence Step 1 Position firebox prior to framing or into prepared framing Step 2 Field wire the main power supply to the appliance if a blower kit is to be installed at the time of installat...

Страница 9: ...hed surface If a wall covering such as drywall is to be attached to the rear wall then the depth must be measured from the drywall surface It is important that this dimension be exact Step 2 Level the...

Страница 10: ...37 1 4 947 23 1 2 597 20 508 3 77 7 3 8 188 15 7 8 404 7 1 2 191 12 305 1 3 8 35 5 1 2 140 30 3 8 772 29 5 8 753 VRT3142WS VRT3142F 42 1067 24 610 47 3 4 1213 37 1 4 947 29 1 2 749 20 508 3 77 7 3 8...

Страница 11: ...creen and rod assemblies see Figure 10 Framing Dimensions Opening VRT3132WS VRT3132F VRT3136WS VRT3136F VRT3142WS VRT3142F A 38 1 4 972 42 1 4 1073 48 1 4 1226 B 40 1 4 1022 40 1 4 1022 40 1 4 1022 C...

Страница 12: ...NG Junction Box Factory Wired Blower Tab Intact Plug blower into this receptacle Ground Green Wall mounted ON OFF Blower Switch or Variable Speed Control Switch Ground HOT SIDE OF RECEPTACLE A ON OFF...

Страница 13: ...igure 16 Step3 Looselytieaknotinthepowercordtotakeupslack seeFigure19 Step 4 Locate the tabs shown in Figure 20 Position the blower assembly so that the tabs located on the cabinet base are seated in...

Страница 14: ...The strain relief bushing not supplied should be pressed into the knock out on J box cover around the Romex thiswillprovideprotectiontothewiresandpreventsstrain against connections from J box See Wir...

Страница 15: ...xtension combustibles allowed No carpet or vinyl Combustible Platform SIDE VIEW Firebox Floor Combustible Wall Figure 23 Raised Hearth Extension Non Combustible Wall see Figure 4 Fireplace Opening Fro...

Страница 16: ...igned to be used when an optional FBK 100 or FBK 200 Blower Kit is to be installed Forced Air Blower Kits Cat No ModelNo Description 80L84 FBK 100 Blower Standard single speed 80L85 FBK 200 Blower Var...

Страница 17: ...e or personal injury NOTE The model and serial number can be found on the rating label located on the bottom left front corner of the appliance If you encounter any problems or have any questions conc...

Страница 18: ..._______________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ___________________...

Страница 19: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard...

Страница 20: ...HP reserves the right to make changes at any time without notice in design materials specifications prices and the discontinuance of colors styles and products Consult your local distributor for firep...

Отзывы: