Step 9.
Follow the instructions below for the kit you are installing:
FBK-100 Kits - Install a locally sourced ON/OFF wall switch in
a convenient location on a wall, near the fireplace.
FBK-200 Kits - Install the kit-provided variable speed control
(rheostat) in a convenient location on a wall, near the fireplace.
Step 10.
Follow the instructions below for the model you are installing:
Reinstall the blower access panel that was removed on
Step 1
(see
Figure 15
).
Step 8.
Ensure that power supply wires are NOT "live" before making
these connections). Install J-Box Cover Plate as follows:
Feed the * Romex wires (or other equivalent plastic insulated
wire - Refer ANSI/NFPA 70 - National Electrical Code - Latest
Edition) through the J-Box Cover rectangular opening, then con-
nect to the J-box wires. The strain relief bushing (not supplied)
should be pressed into the knock-out on J-box cover around the
Romex (this will provide protection to the wires and prevents strain
against connections from J-box). See Wiring Diagram -
Figure
14
. Install the cover plate over J-Box opening on appliance as
shown in
Figure 22
.
NOTE:
Wire connections should be positioned inside of the ap-
pliance.
*
Romex is a plastic insulated wire from power supply - sometimes called
non-metallic sheath.
Cabinet Base
Figure 19
Figure 20
Figure 21
Loose knot in power
cord to take up slack
Locating Tabs
Bend Locating Tabs Over
(into notches)
Use screw provided and
secure in place as shown
The notched side of
cover plates goes inside
firebox panel
Screw
Cover Plate
Right Side Panel of Firebox
Figure 22 -
Installing J-box Cover Plate - All Models
J-Box opening
on appliance
Step 6.
Route a 3-wire, 120 VAC, 60 Hz, 1 ph power supply to the right
side of appliance.
Step 7.
Locate the J-Box cover (provided in J-Box Kit). Remove the round
knock-out (see
Figure 16
).
Firebox