Quick Step Installation Manual

www.heatmaster.com.au

enviro

Quick Step Installation Manual

enviro

4

Openable

Window

Door

T

a

l

a

b

k

Flue Terminal

Indicates areas for flue terminals

c

c

c

c

d

m

g

d

P

M

f

h

h

h

j

j

j

Use 3 bends only

Our flexible flue has the ability to bend 
3 times between the heating unit and 
the cowl. This includes the bend 
straight out of the heater if you’re 
fluing through the ceiling or floor.

Make the flue pipe go over  
the bearers and joists.

You may bend the flue over joists and bearers. 
It is recommended that a 20mm clearance be 
maintained between the smaller gas exhaust 
flue and combustible materials.

Fluing where the pipe had a spot  
lower than the rest.

Never allow a low spot in the flue. 
Installing the flue with a dip or “goose 
neck” can result in reduced efficiency or 
even prevent the fire from working.

2

1

4

3

2

1

4

3

2

1

4

3

Do...

Do...

Never Do...

Do...

Using your flexible flue pipe

The Enviro’s revolutionary flue system incorporates  one 
65mm diameter pipe and one 58mm diameter pipe.

Configure triangle

Addition literature

Supplements for flue installation and heat transfer can be obtained by contacting your Heatmaster dealer.

Key Information – Quick step check list

*All information contained in this mini summary is correct at the time of publication.

 

This is only a summary and should be read in conjunction with the full installation 

instructions. Pictures are representative only and are not drawn to scale. Installation should be carried out by a licensed gas fitter and any electrical work carried out by a 

licensed electrician. 

Minimum clearances required for balanced flue terminals or the flue terminals of outdoor appliances

 

(according to AS5601-2004[AGA gas installation code] or NZS 5261 [New Zealand]

a  Bellow eaves, balconies or other projections 

300 mm

b  From the ground or above a balcony 

300 mm

c  From a return wall or external corner 

500 mm

d  From a gas meter (M) 

1000 mm

e  From an electricaity meter or fuse box (P) 

500 mm

f  From a drain or soil pipe 

150 mm

g  Horizontal from an building structure 

500 mm

h  From any other flue terminal, cowl or combustion air intake  500 mm

j  Horizontally from an openable window, door, or non-mechanical 

air inlet, or any other opening into a building, with the exception of 
sub-floor ventilations 

500 mm

k  Vertically below  an openable widow, door,or non-mechanical  

air inlet, or any other opening into a building, with the exception of 
sub-floor ventilation 

150 mm

l  Minimum horizontal clearance to any surface  

(such as an exterior wall) for vertical terminations 

610 mm

m  Minimum height above roof line for vertical termination  600 mm

0m

1m

2m

3m

4m

4m

3m

2m

1m

Example 1

Example 2

Example 3

1

2

3

A 20mm clearance is recommended from the extraction (smaller) flue to combustibles.

Plumber

Incoming gas connection provided – 1/2 inch BSP male connector

Page 2

Gas input – 4

2

MJ high

 

 

                     3

2

MJ low

Page 2

Manifold pressure 
High (Nat gas) 0.69 Kpa 
Low (Nat gas) 0.

45

 Kpa 

High (LPG) 2.25 KPA Low
 (LPG) 

1

.

38

 KPA

Manifold pressure is factory set. 
To check pressure and adjust 
refer to page 8 of the customer 
operation information & Installation 
instructions.

Electrician

Standard flex 2m, 3 pin plug provided. Requires power point with 
double pole isolation switch.

Page 2

Using up to three bends, use this triangle to 

work out measurements for your 4.5 mtr 

flue. Remember, the first bend out of the 

Heater is counted as one. The Enviro 

can be flued through the roof, wall 

or floor. *See your Heatmaster 

dealer for full details.

Appliance  must be tested for correct operation prior to leaving - minimum 20 minutes.

If appilance cannot be adjusted to preform correctly contact Heatmaster prior to leaving