SuperiorFireplaces.us.com
900719-00B
37
TROUBLESHOOTING
Continued
OBSERVED PROBLEM
POSSIBLE CAUSE
REMEDY
Burner system shuts off. Control
module sounds 2 cycles of 3 beeps.
1. Faulty control module
1. Replace control module.
Burner system shuts off. Control
module sounds 2 cycles of 3 beeps.
1. Remote and control module not
communicating properly
2. Faulty control module
1. Follow Pairing instructions on
Page 27
to re-pair remote to
control module.
2. Replace control module
Burner system shuts off. Control
module sounds 20 beeps.
1. Loss of communication between
control module and remote after
18 minutes.
1. Either the remote is too far from
the burner system or the remote
needs new batteries. The remote
should work within 20 feet of the
burner system. If it does not, re-
place the batteries in the remote
and battery supply box.
Burner system shuts off. Control
module sounds 1 long beep.
1. Control module is too hot
1. Check to see the
fi
replace size
meets the minimum require-
ments. Call technical service.
Burner systems shuts off.
1. The SAFETY temperature set-
ting in the remote has shut the
burner system off.
1. The remote includes a shut off
that is preset at 40C (104F). If
the remote is placed in a loca-
tion that is at or above this tem-
perature it will shut the burner
system off. Placing the remote
on a mantel may result in this
problem. If it occurs, relocate
the remote to a cooler location.
Burner system lights or shuts off
without touching the remote.
1. More than one burner system
is present and operating on the
same frequency.
1. Follow Pairing instructions on
Page 27
to re-pair remote to
control module.