PRODUCT FEATURES
OPERATION
This vent-free
fi
replace is clean burning. It
requires no outside venting. There is no heat
loss out a vent or up a chimney. Heat is gen-
erated by both realistic
fl
ames and glowing
embers. When used without the blower, the
fi
replace requires no electricity making it ideal
for emergency backup heat.
SAFETY DEVICE
This
fi
replace has a pilot with an Oxygen
Depletion Sensing (ODS) safety shutoff
system. The ODS/pilot is a required feature
for vent-free room heaters. The ODS/pilot
system shuts off the
fi
replace if there is not
enough fresh air.
ELECTRONIC IGNITION SYSTEM
This heater has an electronic igniter to light
the
fi
replace's fuel supply.
BLOWER ASSEMBLY
This
fi
replace includes a blower assembly. The
blower operates thermostatically and features
a variable speed control. The blower circulates
heated air from the
fi
replace into the room.
LOCAL CODES
NOTE: Do not pick up appliance base as-
sembly by burners. This could damage the
appliance. Always handle base assembly
by grate.
2. Remove all protective packaging applied
to logs and appliance for shipment.
3. Check appliance for any shipping dam-
age. If appliance is damaged, promptly
inform dealer where you purchased the
appliance.
Install and use appliance with care. Follow all
local codes. In the absence of local codes, use
the latest edition of
The National Fuel Gas
Code, ANSI Z223.1/NFPA 54
*.
*Available from:
American National Standards Institute, Inc.
25 West 43rd Street, 4th
fl
oor
New York, NY 10036
National Fire Protection Association, Inc.
1 Batterymarch Park
Quincy, MA 02169-7471
UNPACKING
1. Remove logs and appliance base assem-
bly from carton(s).
COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS
These appliances are approved for installation in the US state of Massachusetts if the fol-
lowing additional requirements are met:
• Un-vented Room Heaters shall be installed in accordance with 527 CMR 30.
• Installation and repair must be done by a plumber or gas
fi
tter licensed in the Common-
wealth of Massachusetts.
• The
fl
exible gas line connector used shall not exceed 36 inches (92 centimeters) in length.
• The individual manual shut-off must be a T-handle type valve.
• Unvented appliances may NOT be installed in bedrooms or bathrooms.
• A working smoke detector must be installed in the area where vent-free appliances are
installed.
Seller of unvented propane or natural gas-
fi
red supplemental room heaters shall provide
to each purchaser a copy of 527 CMR 30 upon sale of the unit.
CAUTION: Do not remove
the data plates from the grate
assembly. The data plates
contain important warranty
and safety information.