9.
DISASSEMBLY INSTRUCTIONS
WARNING: Ensure that the power cord to the machine has been disconnected before
disassembly
9.1. Disassemble front housing
1. Remove six (6) outside hexagonal screws to take the front housing off of the unit.
9.2. Disassemble back housing and control panel (see pictures below)
STEP #1: Remove the nuts from the axel on each wheel hub. Remove wheels from unit.
STEP #2: Place a support under the unit after removing each wheel to avoid tilting the unit.
STEP #3: Remove the four (4) screws holding the screen and panel in-‐place. Remove label.
STEP #4: Remove two (2) screws attaching to PCB to panel. Pull out lead wire from the PCB.
STEP #1
STEPS #3 & #4
STEP #5 (see below): Remove seven (7) screws to remove the back housing from the unit.
View after
removing the back housing
Tool:
Outside hexagonal
screw sleeve