REPAIR INSTRUCTIONS
WARNINGS:
In the event of failure of an electrical component, contact Ideal Air Support to obtain the
correct replacement part.
Ensure that the power cord to the machine has been disconnected before repairing .
11.1
Replacing the water pump
1. If the water pump does not work, please take off the front housing.
2. See the picture below, and remove two (2) screws.
3. Remove drain tubes connected to the water pump.
4. Remove the pump cover, disconnect the pump and water level sensor, and mark the
sensor wires to help with proper re-‐attachment.
5. Replace the new water pump and re-‐install all wires and tubes.
11.2 Replacing the fan motor
STEP #1. If the motor is not running, first determine the cause. Replace only if required.
STEP #2. Please take off the front and back housings.
STEP #3. As below picture shows, remove four (4) screws to take apart the fan motor
from the unit
STEP #4. Remove one (1) screw to take apart the fan.
STEP #5. Remove six (6) screws to take apart the motor
STEP #6. Replace the motor and re-‐install all items listed above.
water pump
Step #3
Step #4
Step #5