Service Manual Ideal Air CG2 Commercial Grade Dehumidifier
Sunlight Supply, Inc.
16
10.
ROUTINE MAINTENANCE
WARNING: Ensure that the power cord is unplugged from the power outlet before
performing routine maintenance.
IMPORTANT: To ensure continued, efficient operation of the dehumidifier, the
maintenance procedures below should be performed regularly.
10.1. Frequency of maintenance
The working performance of the dehumidifier will be greatly reduced if the filters become
clogged. Please clean the air filter every two months, at minimum. More frequent cleaning
may be needed. Use visual inspection weekly to determine if debris build up has clogged the
filter.
10.2. Cleaning the air filter.
STEP #1: Remove the filter as shown in the diagram below.
STEP #2: Vacuum any debris from the filter.
STEP #3. Use lukewarm water and a mild detergent to wash the filter.
STEP #4: drying.
STEP #5: Re-‐install the filter into the dehumidifier
10.3. Replacing the battery (see images below)
NOTE: Replace the battery every two years, or while time fails to show during operation.
STEP #1: Remove the 4pcs screws in the four corners of the control panel.
STEP #2: Once the screws are removed, carefully remove the control panel to access the
PCB.
STEP #3: On the PCB is a CR2032 battery. Remove the battery and replace with new.
STEP #4: Refit the control panel onto the PCB.
STEP #5: Refit the four screws.
CR2032 battery