55
6.12 RS485 Connection
The RS485 connection is reserved for inverter daisy chain. The availability will be up-
dated in the upcoming manual version.
For detailed connection description, refer to the section
. Plug
the wires into the A
A1
1 and B
B1
1 terminals according the labels on the bottom of the inverter.
6.13 DRM Connection
DRM and Ripple Control support only one function at the same time.
D
DR
RM
M
In Australia and New Zealand, the inverter supports the demand response modes as
specified in the standard AS/NZS 4777.
The following figure shows the wiring between the inverter and the external DRED.
table 6-4
Method of Asserting DRM
M
Mo
od
de
e
A
Asssse
errtte
ed
d b
byy S
Sh
ho
orrttiin
ng
g T
Te
errm
miin
na
allss
o
on
n IIn
nvve
errtte
err
S
Sw
wiittc
ch
h O
Op
pe
erra
attiio
on
n o
on
n E
Exxtte
errn
na
all
D
DR
RE
ED
D
DRM0
R & C
Close S1 and S5
DRM1
D1/5 & C
Close S1
DRM2
D2/6 & C
Close S2
DRM3
D3/7 & C
Close S3
DRM4
D4/8 & C
Close S4
DRM5
D1/5 & R
Close S5
DRM6
D2/6 & R
Close S6
DRM7
D3/7 & R
Close S7
DRM8
D4/8 & R
Close S8
R
Riip
pp
plle
e C
Co
on
nttrro
oll
In Germany, the grid company uses the Ripple Control Receiver to convert the grid dis-
patching signal and send it as a dry contact signal.
Wiring of the ripple control receiver dry contact cables is shown in the figure below:
User Manual