39
step 9
Connect the PE wire to ground and the phase lines and the “N” line to AC circuit
breaker. Then connect the AC circuit breaker to electric board.
step 10
Make sure all wires are firmly installed via the right torque tool or dragging the cables
slightly.
-- -- E
En
nd
d
6.7
DC Cable Connection
Danger of electric shock!
The PV array will generate lethal high voltage once exposed to sunlight.
Make sure the PV array is well insulated to ground before connecting it to the
inverter.
User Manual