Page 51
780 Series
13.5 Panel Displays SN--2
Open or shorted sensor (heater disabled). The temperature
sensor is not functioning. Contact your authorized Sundance
Spas dealer or qualified service technician. The display will alternate
between
“SN--2”,
scrolling message
“WATER SENSOR ERROR”
and
the current water temperature.
13.6 Panel Displays Change CLEARRAY Bulb
The CLEAR
RAY
bulb timer has expired. UV bulb needs to be replaced.
The display will alternate between the current temperature reading and
the scrolling message
“CHANGE CLEARRAY BULB”
as long as the
error exists. The countdown timer for the UV bulb needs to be reset (page
34). A new UV bulb can be purchased from a local Sundance Spas
dealer.
13.7 Panel Displays Change Filter
The filter change timer has expired. The hot tub filters need to be
cleaned or replaced. The display will alternate between the current
temperature reading and the scrolling message
“CHANGE FILTER”
as long as the error exists. The countdown timer for the Change Filter
feature needs to be reset (page 34). New filters can be purchased
from a local Sundance Spas dealer.
13.8 Panel Displays Change Water
The water refresh timer has expired. The hot tub needs to be drained
and refilled. The display will alternate between the current temperature
reading and the scrolling message
“CHANGE WATER”
as long as the
error exists. The countdown timer for the Change Water feature needs
to be reset (page 35).
13.9 Panel Displays FL--1
An
“FL--1”
display means the flow switch is malfunctioning
open, the filter cartridge is excessively dirty or an “air lock”
condition has occurred at the circulation pump intake. The hot tub heater
will deactivate and jets pump #1 may also deactivate. Contact your
authorized Sundance Spas dealer or qualified service technician. The
display will alternate between
“FL--1,”
scrolling message
“FLOW
ERROR OPEN”
and the current water temperature.
13.10 Panel Displays FL--2
An
“FL--2”
display means the flow switch is malfunctioning
closed. The hot tub heater will deactivate and jets pump #1
may also deactivate. Contact your authorized Sundance Spas dealer or
qualified service technician. The display will alternate between
“FL--2,”
scrolling message
“FLOW ERROR CLOSED”
and the current water
temperature.