SPARC T3-1B Server Module Service Manual • July 2012
The following table provides brief descriptions of the troubleshooting actions shown
in the flowchart. The table also provides links to topics with additional information
on each diagnostic action.
TABLE:
Diagnostic Flowchart Reference Table
Diagnostic Action
Possible Outcome
Additional Information
Flowchart item 1.
Check the Power
OK LED.
The Power OK LED is located on the front of the server
module.
If this LED is not lit, check the power source and ensure
that the server module is properly installed in the
modular system chassis.
•
Flowchart item 2.
Run the Oracle
ILOM
show
faulty
command
to check for faults.
The
show faulty
command displays the following
kinds of faults:
• Environmental and configuration faults
• PSH-detected faults
• POST-detected faults
Faulty FRUs are identified in fault messages using the
FRU name.
All Oracle ILOM detected fault messages begin with the
characters “SPT”.
For additional information on a reported fault, including
possible corrective action, go to this web site:
http://www.sun.com/msg/
message-ID
where
message-ID
is the message contained in the fault
message.
•
“Service-Related Oracle
ILOM Command Summary”
on page 21
•
“Check for Faults (show
faulty Command)” on
page 18
Flowchart item 3.
Check the Oracle
Solaris log files for
fault information.
The Oracle Solaris message buffer and log files record
system events, and provide information about faults.
• If system messages indicate a faulty device, replace
the FRU.
• For more diagnostic information, review the VTS
report (flowchart item 4).
•
“Interpreting Log Files and
System Messages” on
page 23
Flowchart item 4.
Run VTS software.
VTS is an application you can run to exercise and
diagnose FRUs. To run VTS, the server module must be
running the Oracle Solaris OS.
• If VTS reports a faulty device, replace the FRU.
• If VTS does not report a faulty device, run POST
(flowchart item 5).
•
“Checking if Oracle VTS
Software Is Installed” on
page 48
Flowchart item 5.
Run POST.
POST performs basic tests of the server module
components and reports faulty FRUs.
•
“Managing Faults (POST)”
on page 31
•
Содержание Netra SPARC T3-1B
Страница 1: ...SPARC T3 1B Server Module Service Manual Part No E29280 02 July 2012 ...
Страница 7: ...Contents vii Start the Server Module Host 114 Glossary 115 Index 121 ...
Страница 8: ...viii SPARC T3 1B Server Module Service Manual July 2012 ...
Страница 12: ...xii SPARC T3 1B Server Module Service Manual July 2012 ...
Страница 100: ...88 SPARC T3 1B Server Module Service Manual July 2012 Related Information Remove a REM on page 85 ...
Страница 116: ...104 SPARC T3 1B Server Module Service Manual July 2012 ...
Страница 131: ...Glossary 119 W WWID World wide identifier A unique number that identifies a SAS target ...
Страница 132: ...120 SPARC T3 1B Server Module Service Manual July 2012 ...