Detecting and Managing Faults
13
Fault Management
Error conditions detected by Oracle ILOM, POST, and the Oracle Solaris PSH
technology are forwarded to Oracle ILOM for fault handling.
The Oracle ILOM fault manager evaluates error messages it receives to determine
whether the condition being reported should be classified as an alert or a fault.
■
Alerts
– When the fault manager determines that an error condition being
reported does not indicate a faulty FRU, the fault manager classifies the error as
an alert.
Alert conditions are often caused by environmental conditions, such as computer
room temperature, which might improve over time. Conditions might also be
caused by a configuration error, such as the wrong DIMM type being installed.
If the conditions responsible for the alert go away, the fault manager will detect
the change and will stop logging alerts for that condition.
■
Faults
– When the fault manager determines that a particular FRU has an error
condition that is permanent, that error is classified as a fault. This condition causes
the Service Action Required LEDs to be turned on, the FRUID PROMs updated,
and a fault message logged. If the FRU has status LEDs, the Service Action
Required LED for that FRU will also be turned on.
You must replace a FRU identified as having a
fault
condition.
In the event of a system fault, Oracle ILOM ensures that the Service Action Required
LED is turned on, FRUID PROMs are updated, the fault is logged, and alerts are
displayed. Faulty FRUs are identified in fault messages using the FRU name.
Fault Clearing
The SP can detect when a fault is no longer present. When this happens, it clears the
fault state in the FRU PROM and extinguishes the Service Action Required LED.
A fault condition can be removed in two ways:
■
Unaided recovery
– Faults caused by environmental conditions can clear
automatically if the condition responsible for the fault is no longer present.
Содержание Netra SPARC T3-1B
Страница 1: ...SPARC T3 1B Server Module Service Manual Part No E29280 02 July 2012 ...
Страница 7: ...Contents vii Start the Server Module Host 114 Glossary 115 Index 121 ...
Страница 8: ...viii SPARC T3 1B Server Module Service Manual July 2012 ...
Страница 12: ...xii SPARC T3 1B Server Module Service Manual July 2012 ...
Страница 100: ...88 SPARC T3 1B Server Module Service Manual July 2012 Related Information Remove a REM on page 85 ...
Страница 116: ...104 SPARC T3 1B Server Module Service Manual July 2012 ...
Страница 131: ...Glossary 119 W WWID World wide identifier A unique number that identifies a SAS target ...
Страница 132: ...120 SPARC T3 1B Server Module Service Manual July 2012 ...