Detecting and Managing Faults
9
Related Information
■
SPARC T3 Series Servers Administration Guide
■
“Diagnostics Overview” on page 5
■
Flowchart item 6.
Check if the fault is
environmental.
Determine if the fault is an environmental fault or a
configuration fault.
If the fault listed by the
show faulty
command
displays a temperature or voltage fault, then the fault is
an environmental fault. Environmental faults can be
caused by faulty FRUs, or by environmental conditions
such as when computer room ambient temperature is
too high, or airflow is blocked. When the environmental
condition is corrected, the fault will automatically clear.
For additional information on a reported fault, including
possible corrective action, go to this web site:
http://www.sun.com/msg/
message-ID
where
message-ID
is the message contained in the fault
message.
•
“Check for Faults (show
faulty Command)” on
page 18
Flowchart item 7.
Determine if the
fault was detected
by PSH.
If the fault message does not begin with the characters
“SPT”, the fault was detected by the PSH feature.
For additional information on a reported fault, including
possible corrective action, go to this web site:
http://www.sun.com/msg/
message-ID
where
message-ID
is the message contained in the fault
message.
After the FRU is replaced, perform the procedure to
clear PSH detected faults.
•
“Managing Faults (Oracle
Solaris PSH)” on page 25
•
“Clear PSH-Detected
Faults” on page 30
Flowchart item 8.
Determine if the
fault was detected
by POST.
POST performs basic tests of the server module
components and reports faulty FRUs. When POST
detects a faulty FRU, POST logs the fault and if possible,
takes the FRU offline. POST detected FRUs display the
following text in the fault message:
Forced fail
reason
where
reason
is the name of the power-on routine that
detected the failure.
•
“Managing Faults (POST)”
on page 31
•
“Clear POST-Detected
Faults” on page 40
Flowchart item 9.
Contact technical
support.
The majority of hardware faults are detected by the
server module’s diagnostics. In rare cases a problem
might require additional troubleshooting. If you are
unable to determine the cause of the problem, contact
your service representative for support.
•
“Support and Accessibility”
on page xi
TABLE:
Diagnostic Flowchart Reference Table
(Continued)
Diagnostic Action
Possible Outcome
Additional Information
Содержание Netra SPARC T3-1B
Страница 1: ...SPARC T3 1B Server Module Service Manual Part No E29280 02 July 2012 ...
Страница 7: ...Contents vii Start the Server Module Host 114 Glossary 115 Index 121 ...
Страница 8: ...viii SPARC T3 1B Server Module Service Manual July 2012 ...
Страница 12: ...xii SPARC T3 1B Server Module Service Manual July 2012 ...
Страница 100: ...88 SPARC T3 1B Server Module Service Manual July 2012 Related Information Remove a REM on page 85 ...
Страница 116: ...104 SPARC T3 1B Server Module Service Manual July 2012 ...
Страница 131: ...Glossary 119 W WWID World wide identifier A unique number that identifies a SAS target ...
Страница 132: ...120 SPARC T3 1B Server Module Service Manual July 2012 ...