Sun Microelectronics
374
UltraSPARC User’s Manual
F
EDATA pins 338 to 339
EDATA signals 341, 343
edge handling instructions 219
edge mask encoding 220
little-endian 221
EDGE16 instruction 219
EDGE16L instruction 219
EDGE32 instruction 219
EDGE32L instruction 219
EDGE8 instruction 219
EDGE8L instruction 219
EDPAR pins 338 to 339
EDPAR signals 341, 343
Enable D-MMU (DM) field of LSU_Control_
Register 19, 307
Enable Floating-Point (PEF) field of PSTATE
register 198, 304
Enable I-MMU (IM) field of LSU_Control_
Register 307
endianness 42
Energy Star compliance 327
enhanced security environment 240
EPD pin 338, 341
EPD signal 342
Error Correcting Code (ECC)
generated and checked by UDB 76
Error Correcting Code (ECC) byte addresses
within quadword
illustrated 76
Error Correction Code (ECC) 75
generation and checking 10
error correction code (ECC) 18
error_state 169, 236
error_state processor state 171
ESTATE_ERR_EN Register 170
ESTATE_ERR_EN register 252
Exclusive (E) state 80 to 82
Execute (E) Stage 14
illustrated 11
Execution (E) Stage 14
EXPAND instruction 206
EXT_EVENT signal 342 to 343
extended (non-SPARC-V9) ASIs 147
extended floating-point pipeline 11
extended instructions 3, 253
Extended Interrupt Target ID 117
external cache 4, 18
External Cache (E-Cache) 8, 14
External Cache Unit (ECU) 8
illustrated 5
external power-down (EPD) signal 196, 328
External Reset pin 169
Externally Initiated Reset (XIR) 169, 171, 239
externally_initiated_reset
trap 158
F
FALIGNDATA instruction 214, 228
false errors 176
FAND instruction 215
FANDNOT1 instruction 215
FANDNOT1S instruction 215
FANDNOT2 instruction 215
FANDNOT2S instruction 215
FANDS instruction 215
fast_data_access_MMU_miss
trap 47 to 48, 60, 159
fast_data_access_protection
trap 47 to 48, 63, 159,
252
fast_instruction_access_MMU_miss
trap 47 to 48, 60,
159, 252
fatal errors 175
Fatal Errors (P_FERR) 119, 130
Fault Address field of SFAR 61
Fault Type (FT) field of SFSR register 31, 34 to 36,
58
, 248, 303, 310
Fault Type (ft) field of SFSR register 49
Fault Valid (FV) field of SFSR register 60
Fault_Address, see Fault_Address field of SFAR
register
fcc, see Floating-Point Condition Code (fcc) field of
FSR register
fcc0, see Floating-Point Condition Code 0 (fcc0) field
of FSR register
fcc1, see Floating-Point Condition Code 1 (fcc1) field
of FSR register
fcc2, see Floating-Point Condition Code 2 (fcc2) field
of FSR register
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com