40
Sun Fire T2000 Server Installation Guide
• April 2006
■
netsc_ipnetmask
– Netmask for the system controller subnet
■
netsc_ipaddr
– IP Address of the system controller
■
netsc_ipgateway
– IP address of the gateway for the subnet
■
if_network
– Specified whether the SC is on the network or not
To configure these parameters you must use the
setsc
command. The usage is:
setsc
parameter
1. Set the netmask for the system controller.
This example uses
255.255.255.0
to set the netmask. Your network environment
subnet might require a different netmask. Use a netmask number most appropriate
to your environment.
2. Set the IP address for the system controller.
3. Set the IP address for the system controller gateway.
4. Set the
if_network
parameter to
true
.
5. Use the
showsc
command to verify that the parameters were set correctly.
The
showsc
command displays all the configuration parameters and their values, as
listed in
sc>
setsc netsc_ipnetmask 255.255.255.0
sc>
setsc netsc_ipaddr
service-processor-IPaddr
sc>
setsc netsc_ipgateway
gateway-IPaddr
sc>
setsc if_network true
Содержание Sun Fire T200
Страница 6: ...vi Sun Fire T2000 Server Installation Guide April 2006...
Страница 10: ...x Sun Fire T2000 Server Installation Guide April 2006...
Страница 14: ...xiv Sun Fire T2000 Server Installation Guide April 2006...
Страница 16: ...xvi Sun Fire T2000 Server Installation Guide April 2006...
Страница 29: ...Chapter 1 Preparing for Installation 9 FIGURE 1 5 Locating the Locks on the Slide Rail Assembly...
Страница 54: ...34 Sun Fire T2000 Server Installation Guide April 2006...
Страница 70: ...50 Sun Fire T2000 Server Installation Guide April 2006...
Страница 80: ...60 Sun Fire T2000 Server Installation Guide April 2006...